Determine the design flood discharge (allowing an increase of one third) for a bridge site with the following data : catchment area = 2 x 105 hectares, duration of storm = 8 hr, storm precipitation = 3 cm, time of concentration = 2 hr, gauged discharge for a past flood with average maximum daily rainfall of 18 cm was 3400 m3/sec.
Determine the design flood discharge (allowing an increase of one third) for a bridge site with the following data : catchment area = 2 x 105 hectares, duration of storm = 8 hr, storm precipitation = 3 cm, time of concentration = 2 hr, gauged discharge for a past flood with average maximum daily rainfall of 18 cm was 3400 m3/sec.