Q. In the figure below, an 11 kV ring network is powered by a 10MVA generator with a reactance 16.5 pu. Overcurrent protection is used for keys S1, S2, S3 and S4. The time characteristics of the relays installed on the switches S1 to S4 are as follows S1,52,54 I.T=16.66 S3 I.T =25.4 The conversion ratio of protection current transformers is 250/50. The impedance of the lines is also indicated on the figure. If a short-circuit three-phase symmetric connection occurs at point F, Determine which of the keys is disconnected in order and the time of disconnection of each of them. Is local protection provided? X-16.5% 10 MVA. 11 kV Le j2 j3

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question
I need the answer as soon as possible
Q. In the figure below, an 11 kV ring network is powered by a 10MVA generator with a reactance 16.5%
pu. Overcurrent protection is used for keys S1, s2, S3 and S4. The time characteristics of the relays
installed on the switches S1 to S4 are as follows
S1 52,54 I.T=16.66
S3
I.T=25.4
The conversion ratio of protection current transformers is 250/50. The impedance of the lines is also
indicated on the figure. If a short-circuit three-phase symmetric connection occurs at point F,
Determine which of the keys is disconnected in order and the time of disconnection of each of them.
Is local protection provided?
X-16.5%
10 MVA, 11 kV
Le
j2
12
Sa
j2
j3
Transcribed Image Text:Q. In the figure below, an 11 kV ring network is powered by a 10MVA generator with a reactance 16.5% pu. Overcurrent protection is used for keys S1, s2, S3 and S4. The time characteristics of the relays installed on the switches S1 to S4 are as follows S1 52,54 I.T=16.66 S3 I.T=25.4 The conversion ratio of protection current transformers is 250/50. The impedance of the lines is also indicated on the figure. If a short-circuit three-phase symmetric connection occurs at point F, Determine which of the keys is disconnected in order and the time of disconnection of each of them. Is local protection provided? X-16.5% 10 MVA, 11 kV Le j2 12 Sa j2 j3
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY