The flux density distribution in the air-gap of a certain generator is such that it contains a fundamental, a third harmonic, and a fifth harmonic. The flux per pole due to the fundamental distribution is 9 x 10-3 weber, that due to the third harmonic distribution is 0.9 x 10-3 weber, that due to the fifth harmonic distribution is 0.4 x 10-3 weber. There are four armature slots per phase per pole, the connection are made for three-phase wye, and the coil pitch is 12/15. The frequency is 60 cycles and the generator has 4 poles. (a) Calculate the emf/turn. (b) If there are six turns/coil and two coil sides/slot, calculate the emf per phase. (c) Calculate the emf between line terminals.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
9.09 The flux density distribution in the air-gap of a certain generator is such that it contains
a fundamental, a third harmonic, and a fifth harmonic. The flux per pole due to the
fundamental distribution is 9 x 10-3 weber, that due to the third harmonic distribution
is 0.9 x 10-3 weber, that due to the fifth harmonic distribution is 0.4 x 103 weber. There
are four armature slots per phase per pole, the connection are made for three-phase wye.
and the coil pitch is 12/15. The frequency is 60 cycles and the generator has 4 poles. (a)
Calculate the emf/turn. (b) If there are six turns/coil and two coil sides/slot, calculate
the emf per phase. (c) Calculate the emf between line terminals.
Ans. 2.32V; 212V; 364V
Transcribed Image Text:9.09 The flux density distribution in the air-gap of a certain generator is such that it contains a fundamental, a third harmonic, and a fifth harmonic. The flux per pole due to the fundamental distribution is 9 x 10-3 weber, that due to the third harmonic distribution is 0.9 x 10-3 weber, that due to the fifth harmonic distribution is 0.4 x 103 weber. There are four armature slots per phase per pole, the connection are made for three-phase wye. and the coil pitch is 12/15. The frequency is 60 cycles and the generator has 4 poles. (a) Calculate the emf/turn. (b) If there are six turns/coil and two coil sides/slot, calculate the emf per phase. (c) Calculate the emf between line terminals. Ans. 2.32V; 212V; 364V
Expert Solution
steps

Step by step

Solved in 6 steps

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,