What kinds of Differential Pressure Flow meters? And discuss them.
Q: Is there a significant difference between the discharge coefficient derived from the experiment with…
A: Yes, there is a significant difference between the discharge coefficient derived from the…
Q: Air 250 mm Water 150 mm diam 1) 2) 300 mm diam wwww wwwws
A:
Q: How can you determine the velocity of the flow in the channel with the venturimeter in the pire…
A:
Q: Question 5: The velocity of a fluid flowing in a pipe is to be measured by two different Pitot-type…
A: From these two arrangements for water as a fluid 2nd arrangement will give more accurate result as…
Q: The energy grade line for steady flow in a uniform-diameter pipe is shown. Which of the following…
A: Energy Gradient Line(EGL) EGL is the graphical representation of sum of static pressure head and…
Q: Water is flowing through a pipe of 100 mm diameter under a pressure of 19.62 N/cm? (gauge) and with…
A: We are authorized to answer one question at a time since you have not mentioned which question you…
Q: A nozzle meter, with an orifice diameter of 3 cm, is being used to determine the velocity of ethanol…
A: Write the given data with suitable variables: Do=3 cm=0.03 mSG=0.789μ=0.986×10-3 Pa-s100 cm1 mD1=6…
Q: A horizontal venturimeter with inlet diameter 30 cm and throat diameter 15 cm is used to measure the…
A:
Q: Write the equation that defines actual (available) net positive suction head NPSH. From this…
A: NPSH-it stands for the Net positive suction head. apply Bernoulli equation at point 1 and 2
Q: 5.9.5. Factory tests indicated that a cavitation parameter for a particular pump is o = 0.075. The…
A: Given: Cavitation parameter for the pump→σ=0.075 Pressure at the sea level→Patm=101.325 KPa…
Q: Q2: A horizontal venturimeter with inlet diameter 20 cm and throat diameter 10 cm is used to measure…
A:
Q: peton with a relative density of 0.78 flows upward in a vertical venturimeter having a discharge…
A:
Q: Explain how flow rate is measured with obstruction-type flowmeters. Compare orifice meters, flow…
A: In obstruction type flowmeters, the pipe contained a contracted area. When the flow is carried out…
Q: For a piping system, define the system curve, the characteristic curve, and the operating point on a…
A: Draw the system curve, the characteristic curve, and the operating point on a head versus flow rate…
Q: 1. Why is discharge coefficient always less than 1. 2. What is the difference between discharge…
A: DISCHARGE release pipe - a line through which liquids can be released. hydrant - a release pipe with…
Q: The venturi meter experiment observation readings are 304 mm, 286 mm, and the flow meter reads 166…
A: Given,h h1=304 mm=0.304 mh2=286 mm=0.286 m Q=166 liter/hr=166×0.0013600 m3/s=4.611×10-5 m3/s…
Q: The flow rate of the water flowing through the venturi, which has a wide section of 4.91x10^-4 m, is…
A:
Q: (a) Prove that the loss of pressure head for the viscous flow through a circular pipe is given by…
A:
Q: What is the flow rate of the oil (sg = 0.73) in the pipe below based on the measurements in the…
A: Find the flow rate.
Q: Q2// A Venturi meter is to be fitted to a 12.5 cm radius pipe, in which the maximum velocity is 2.44…
A:
Q: (B) Explain how flow rate is measured with obstruction type flowmeters. Compare orifice meters, flow…
A: Flow meters are very important for measuring the properties of a flow. There are different types of…
Q: What is the volumetric discharge rate of the tank shown? The coefficient of contraction for the…
A:
Q: The ratio of actual discharge to theoretical discharge through an orifice is coefficient of…
A: Given, In the given statement it is asked If the ratio of actual discharge to theoretical discharge…
Q: An oil of sp. gr. 0.8 is flowing through a venturimeter having inlet diameter 20 cm and throat…
A: Venturi-meter is a device used for measuring the flow of fluid through pipe. Principle: By reducing…
Q: A smooth pipe carries water at the rate of 300 L/s, kinematic viscosity is 10 m/s , with a head loss…
A: Given, Q = 300 L/s = 0.3 m3/s Kinematic viscosity = v = 10-6 m2/s Head loss = hf = 3 m Length of…
Q: Explain how flow rate is measured with a turbine flowmeter, and discuss how they compare to other…
A: For measuring flow rate we have many flow meter and one of them is Turbine flow meter. As from the…
Q: An oil of specific gravity 0.8 is flowing through venturimeter having inlet diameter 20 cm and…
A: An oil with a specific gravity of 0.8 is known to flow through a venturimeter with a 10 cm intake…
Q: 3. If the flow rate of the fluid flowing through a 10 cm diameter iron pipe is 0.04 m^3/s, calculate…
A:
Q: 1) Which of the following statement is NOT correct about piping network? a) In parallel pipes, the…
A: Solution: The correct answers with necessary explanations are given below:
Q: A 0.5-inch diameter water pipe is 18 m long and delivers 19 L/min. What fraction of this pipe is…
A: Given: Diameter of the pipe (D)=0.5in or 0.0127m Flowrate Q=19L/min Length of the pipe (L)=18m
Q: As flowmeters, these devices measure the change in pressure across a special flow element. Velocity…
A: Correct answers: (i)Velocity meter (v) differential pressure meters
Q: fLUID MECAHNICS The flow in the piping system shown is 10 mgd. Determine (a) the head loss from…
A: Since you have asked multiple question, we will solve three part for you. If you want any specific…
Q: The venturi meter experiment observation readings are 309 mm, 286 mm, and the flow meter reads 170…
A:
Q: Explain the concept of Hydraulic Pressure and be sure to justify answer by relating it to the…
A: The hydraulic pressure is the force per unit area of liquid on a surface of contact with liquid. Let…
Q: В4. An orifice meter with orifice area 1039 mm2 is inserted in a pipe of area 2078 mm2 .The pressure…
A:
Q: The venturi meter experiment observation readings are 308 mm, 285 mm, and the flow meter reads 165…
A:
Q: A venturi meter equipped with a differential mercury manometer is shown in Fig. 14-5. At the inlet,…
A: Given data: The diameter at point 1 is d1=12 cm=0.12 m The diameter at point 2 is d2=6 cm=0.06 m The…
Q: 1.1 Pelton with a relative density of 0,78 flows upwards in a vertical venture-meter having a…
A:
Q: The venturi meter experiment observation readings are 303 mm, 289 mm, and the flow meter reads 174…
A:
Q: The venturi meter experiment observation readings are 318 mm, 288 mm, and the flow meter reads 173…
A:
Q: he speed of water in a pipe of about 3 meters in diameter can be measured by a. pitot tube b.…
A: the pitot tube is basically used to ensure the velocity of the fluid at any instant with respect to…
Q: Calculate the pressure differential and head loss in a 70-cm-diameter pipe using a 40-cm-diameter…
A:
Q: Explain the measuring the pressure drop across a flow section or a flow device by a differential…
A: The figure below shows the differential manometer, It is considered that the density of the water…
Q: Describe and Draw Energy Grade Line (EGL) &Hydraulic Grade Line (HGL) Describe and write the…
A: given:
Q: A venturi meter equipped with a differential mercury manometer is shown in Fig. 14-5. At the inlet,…
A: Given details: d1=12 cmd2=6 cmh=22 cm
Q: It is desired to display the flow in the venturimeter, How can you determine this? Explain by…
A:
Q: Using a flexible drinking straw and a ruler, explain how you would measure the water flow velocity…
A: Given Data⇒flexible drinking straw and a rulerProblem definition⇒Problem says explain how you would…
Step by step
Solved in 2 steps with 3 images
- The primary function of the venturi meter is to measure flow rate. Show that the venturi meter in the figure below does not necessarily require the venturi meter's inclination to measure flow rate.a. Certain fluid is flowing in a circular pipe w/ Reynolds no. of 400. What will happen to the frictional pressure loss in the pipe if pipe length (L) is doubled? b. Certain fluid is flowing in a circular pipe w/ Reynolds no. of 400. What will happen to the frictional pressure loss in the pipe if vol. flow rate (Q) is doubled?H. 3 2. What are the relative advantages of using a Venturi meter to measure flow compared with an orifice meter?
- When ventilating the patient on a time-cycled/pressure-limited ventilator, what parameters determine the tidal volume delivered? How can these values increase tidal volume? How can they decrease tidal volume?Toplam basınç göstergesi Manometre Vana Venturimetre Debiölçer Hazne Pompa Manometre=Manometer Ventwrimetre=Ventwrimeter Debiölçer-Flow meter Vana=Valve. Pompa=Pump Hazne=Tank Toplam Basınç Göstergesi =Total Pressure Gauge How can you determine the flow rate in the channel with the venturimeter in the pipe circuit in the figure?Explain the operating principles of a venturi flowmeter. Derive the flow equation.
- 1. Which of the following is used to increase flow velocity from a pipe?Group of answer choices Venturimeter Orifice Nozzle Pitot tube 2. Which of the following is normally used for very large discharge flow measurements?Group of answer choices Nozzle Orifice Venturimeter Pitot tubeA 400 gpm piping system is composed of the following pipes and fittings. Using the chart; Determine the Following: a. Equivalent length at suction in ft b. Equivalent length at discharge in ft c. Total friction loss in the installation, in ft. Suction side (4.5” Փ) Length of straight pipe 210 ft Long sweep elbow 5 pcs Standard Tee 2 pcs Globe valve 1 pc Checked valve 1 pc Gate valve (fully open) 1 pc Discharge side (4.0” Փ) Straight pipe 200 ft Standard elbow 4 pcs Standard Tee 3 pcs Gate valve (fully open) 1 pc1. Why is discharge coefficient always less than 1. 2. What is the difference between discharge coefficient of Orifice Plate Meter and Venturi Meter if both have the same internal diameter and experience the same flow rate. Which one has a higher loss of energy? 3. What would you expect on the effect of changing the diameter (Larger and smaller) of the orifice on the discharge coefficient?
- What is the volumetric flow rate of oil in a 12m diameter pipe? The velocity of the oilis 5m/s.Water is flowing at a velocity of 1 m/s in a pipe 0.4 m in diameter. In the pipe is an orifice with a hole diameter of 0.2 m. What is the measured pressure drop across the orifice?A. 1.76 psiB. 2.21 psiC. 2.83 psiD. 3.76 psiIn the hydronic system given below, the flow rate through 2 1/2 " pipe between A and B is: (a) 10 GPM (b) 15 GPM (c) 35 GPM (d) None of the above