When the outdoor temperatures are 40 ° C DBT and 26 ° C WBT , an air conditioning system is used to maintain a building at 25 ° C DBT and 50 % RH. In a conditioned building , the sensible load is 100 kW , while the latent load is 20 kW. 14% of the outdoor air is mixed with 86% of the return air on a mass basis. Before it is supplied to the conditioned zone, the mixed air is cooled by a cooling coil. During this process, the temperature of chilled water inside the coil increased by 5.6 ° C. (1) The condition of the air after supply, (2) The required cooling capacity in tons, (3) The rate at which chilled water passes through the cooling coil, (4) The By-pass factor of the cooling coil, and (5) The air flow rate required for ventilation .

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter36: Refrigeration Applied To Air-conditioning
Section: Chapter Questions
Problem 9RQ: What are higher-efficiency refrigerant blends that can be used as long-term replacements for R-22 in...
icon
Related questions
Question
I need the answer as soon as possible
When the outdoor temperatures are 40 ° C
DBT and 26 ° C WBT , an air conditioning
system is used to maintain a building at 25 °
C DBT and 50 % RH. In a conditioned
building , the sensible load is 100 kW , while
the latent load is 20 kW. 14% of the outdoor
air is mixed with 86% of the return air on a
mass basis. Before it is supplied to the
conditioned zone, the mixed air is cooled by
a cooling coil. During this process, the
temperature of chilled water inside the coil
increased by 5.6 ° C. (1) The condition of
the air after supply, (2) The required cooling
capacity in tons, (3) The rate at which chilled
water passes through the cooling coil, (4)
The By-pass factor of the cooling coil, and
(5) The air flow rate required for ventilation .
Transcribed Image Text:When the outdoor temperatures are 40 ° C DBT and 26 ° C WBT , an air conditioning system is used to maintain a building at 25 ° C DBT and 50 % RH. In a conditioned building , the sensible load is 100 kW , while the latent load is 20 kW. 14% of the outdoor air is mixed with 86% of the return air on a mass basis. Before it is supplied to the conditioned zone, the mixed air is cooled by a cooling coil. During this process, the temperature of chilled water inside the coil increased by 5.6 ° C. (1) The condition of the air after supply, (2) The required cooling capacity in tons, (3) The rate at which chilled water passes through the cooling coil, (4) The By-pass factor of the cooling coil, and (5) The air flow rate required for ventilation .
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Dimensional Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning