you are asked to design a heating system for a swimming pool that is 2m deep 25 m long and 25 m wide. your client desires that the heating system to be large enough to raise the water temperature from 20 to 30° C in 3h.the rate of heat loss from the water to the air at the outdoor design conditions is determined to be 960W/m^2 and the heater must also be able to maintain the pool at 30° C at those conditions.heat loses to the ground are expected to be small and can be disregarded.the heater considered is a natural gas furnace whose efficiency is 80 percent. what heater size (in kW input) would You recommend tO YOur client?

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter6: Forced Convection Over Exterior Surfaces
Section: Chapter Questions
Problem 6.8P
icon
Related questions
Question
you are asked to design a heating system for a
swimming pool that is 2m deep 25 m long and 25 m
wide. your client desires that the heating system to
be large enough to raise the water temperature from
20 to 30° C in 3h.the rate of heat loss from the water
to the air at the outdoor design conditions is
determined to be 960W/m^2 and the heater must
also be able to maintain the pool at 30° C at those
conditions.heat loses to the ground are expected to
be small and can be disregarded.the heater
considered is a natural gas furnace whose efficiency
is 80 percent. what heater size (in kW input) would
you recommend to your client?
Transcribed Image Text:you are asked to design a heating system for a swimming pool that is 2m deep 25 m long and 25 m wide. your client desires that the heating system to be large enough to raise the water temperature from 20 to 30° C in 3h.the rate of heat loss from the water to the air at the outdoor design conditions is determined to be 960W/m^2 and the heater must also be able to maintain the pool at 30° C at those conditions.heat loses to the ground are expected to be small and can be disregarded.the heater considered is a natural gas furnace whose efficiency is 80 percent. what heater size (in kW input) would you recommend to your client?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning