1 2 X₁ = 0.2 XL = 0.3 V = 1.0 озе 00 XL2-0.3 X'=0.3 A 50Hz synchronous generator having inertia constant H=5MJ/MVA and a direct axis transient reactance X = 0.3 per unit is connected to an infinite bus through a purely reactive circuit as shown above. Reactances in per unit on a common system base are marked on the diagram. The generator is delivering real power P = 0.8 per unit and Q = 0.074 per unit to the infinite bus at a voltage V = 1.0 per unit when a 3- phase fault occurs at the receiving end. Determine the critical clearing angle.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.34P
icon
Related questions
Question
X₁ = 0.2
1
XL = 0.3
V = 1.0
озе
00
XL2-0.3
X'=0.3
A 50Hz synchronous generator having inertia constant H=5MJ/MVA and a direct
axis transient reactance X = 0.3 per unit is connected to an infinite bus through a
purely reactive circuit as shown above. Reactances in per unit on a common system
base are marked on the diagram. The generator is delivering real power P = 0.8 per
unit and Q = 0.074 per unit to the infinite bus at a voltage V = 1.0 per unit when a 3-
phase fault occurs at the receiving end. Determine the critical clearing angle.
Transcribed Image Text:X₁ = 0.2 1 XL = 0.3 V = 1.0 озе 00 XL2-0.3 X'=0.3 A 50Hz synchronous generator having inertia constant H=5MJ/MVA and a direct axis transient reactance X = 0.3 per unit is connected to an infinite bus through a purely reactive circuit as shown above. Reactances in per unit on a common system base are marked on the diagram. The generator is delivering real power P = 0.8 per unit and Q = 0.074 per unit to the infinite bus at a voltage V = 1.0 per unit when a 3- phase fault occurs at the receiving end. Determine the critical clearing angle.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Knowledge Booster
Compensation Techniques in Transmission Line
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning