13. Determine the design strength of the connection shown below. Only check for bolt shear, bearing at bolt hole, and tearing at bolt hole. Don't worry about block shear or about the failure of the tension member. in 3in 3 in 3m 2in PLIX12 P2
Q: The figure shows a rigid bar that is supported by a pin at A and two rods, one made of steel and the…
A:
Q: The presence of water in cracks and transverse joint in rigid pavement causes a part of build-up of…
A: Solution Due to the presence of water, soil and other loose materials on the effect of repeated…
Q: Adjust the traverse using the TRANSIT RULE. Determine the following: a) Sketch of the traverse b.…
A:
Q: Which of the following statements is correct about the given structure? 4. A В C pin fixed roller…
A: Need to find out degree of indeterminacy
Q: A long chord of a compound curve is 150 m long and the angle it makes with the longer and shorter…
A:
Q: A 3-m-wide, 8-m-high rectangular gate CD is located at the end of a rectangular passage that is…
A:
Q: 4) A trailer and truck combination having the axle loads figure rolls across a simply supported beam…
A: Maximum shear force occurs at any support either A or B Ordinates are shown in the ILD diagram of…
Q: How can you provide for the early detection of fire? Why is it important?
A: A fire detection system that provides an early warning of a potential fire. A plan that will ensure…
Q: Given in the accompanying tabulation are the adjusted latitude and adjusted departure of a closed…
A:
Q: A concrete beam of rectangular cross section 14 in x 24 in is to be reinforced with bonded…
A:
Q: What will be the designed section of a pier cap (Let b = h/2) for a simply supported 25-meter span…
A: Given, L = 25 m γc = 23.6 kN/m3
Q: Given the space truss, find the force member AB in kN?
A: Solution-The given diagram is shown below, To Determine The force in member AB in kN
Q: direction of the AB, CD and EF. 65 14 12 m 20 m B. 25 105 23 A
A: an open traverse ABCDEF is given as shown in figure above, azimuth of DE is given and it has been…
Q: A posttensioned concrete beam with section shown contains prestressing cables 800 mm² with initial…
A:
Q: A posttensioned concrete beam with section shown contains prestressing cables 800 mm² with initial…
A: Answer We are given Area of cables = 800 mm2 Initial Prestress force = 100 Mpa Beam span L =16 m…
Q: The beam is loaded as shown in the figure. Derive the shear and bending moment equations and draw…
A:
Q: The beam is loaded as shown in the figure. Derive the shear and bending moment equations and draw…
A:
Q: From the table shows a summary of plastic limit test. Compute the plasticity limit. Plastic Limit…
A:
Q: Two forces L (parallel to the y-axis) and A (parallel to the z-axis) are applied at point Q on the…
A: Option (C) is correct.
Q: Q2: Determine the reactions at the supports using the force method. El is constan (Take Dy as a…
A:
Q: At what percentage of compressive strength of concrete do the tensile cracks move farther upward a.…
A: Following is required answer :
Q: The bearing of the back tangent of a simple curve is S 78°15' E while the forward tangent has a…
A: Given There is a simple circular curve given in the question. Our aim is to determine the the…
Q: stion 1 on thread is subjected to a 9.01-N tension force. Knowing that E 3.3 GPa and that the length…
A:
Q: Which of the following gives the reaction at C in the given beam?
A:
Q: A pump pumps 0.200 ft /s of brine solution having a density of 1.15 g/cm from an open feed tank…
A: ρ = 1.15 x 1000 = 1150kg/m3 Q = 0.2ft3/s = 0.2 x (0.30483) m3/s = 0.00566 m3/s Ho (total head) = H…
Q: 4. Assume that the section has cracked, and use the transformed area to calculate the flexural…
A: We need to find out Flexural stresses at compression and tension zone.
Q: 1. The following set of level notes is to be completed by employing the rise and fall method. Based…
A:
Q: Problem: In the figure shown, determine the value of P acting to the left tat is required to pull…
A:
Q: For a given sandy soil with maximum and minimum void ratios of 0.76 and 0.43 respectively has a…
A:
Q: Link AB is to be made of steel for which the normal stress is 450 MPa. Determine the cross-sectional…
A:
Q: Design a round spiral column to support an axial dead load of 450kN and an axial live load of…
A:
Q: A rectangular concrete beam has a width of 300 mm and an effective depth of 550 mm. The beam is…
A:
Q: Example A 60-watt bulb is switched on 24 hours a day and there is another 60-watt bulb that is…
A:
Q: How can you provide for prompt extinguishment of fire?
A: There are following ways for prompt extinguishment of fire .
Q: Explain how the compressibility (consolidation) characteristics of a clay soil may be examined in…
A:
Q: Determine the MEMBER END MOMENTS AND REACTIONS for the beam shown below using the MOMENT…
A:
Q: The timber member has a cross-sectional area of 1653 mm2 and its modulus of elasticity is 12.9 GPa.…
A: Calculate the axial force in each of the segments of the given bar. Then using the algebraic sum of…
Q: A stone is thrown vertically into the air from a tower 30 m high with initial velocity 15 m/s.…
A:
Q: Homeworks of chapter 5 2.The effective stress parameters for a fully saturated clay are known to be…
A:
Q: PROBLEM 2: Calculate the components of the forces at B and C. В D E A
A:
Q: a venturi meter having a diameter of 6 in, at the throat is installed in a horizontal 18-in. water…
A: Here Sm = manometric fluid Sf = flowing fluid a) Discharge when friction is neglected,…
Q: Use the Analysis of Indeterminate Structures: MOMENT DISTRIBUTION METHOD ONLY Determine the moments…
A:
Q: The steel frame shown has a diagonal brace BD with an area of 1920 sq.mm. Determine the largest…
A:
Q: Given: Determine the distance x bar to the centroid for the beam's cross-sectional area, then find…
A:
Q: Determine the value of dry unit weight if bulk unit weight of soil is 19.28 KN/m3 and water content…
A: Given data : The water content of soil w=0.525 The value of bulk unit weight γ=19.28 KN/m3…
Q: Calculate the forces in the required members of the truss F1 F2 H h В 4 @ S kN use 2 decimal places…
A:
Q: The ultimate load, Qu (assume two-way eccentricity) for a square foundation as shown in Figure, with…
A:
Q: Symmetrical rectangular section of post tension beam of 9 m span, supported at one fixed end. The…
A: Let a be the area of strand in mm2
Q: From the table shows a summary of a liquid limit and plastic limit test. Compute the liqu limit.…
A: Given that Liquid limit casagrande apparatus test results Liquid limit is a water content at which…
Q: Problem II. Refer to the beam shown below. 36 kN/m q (kN/m) P (kN) 162 kN 6 m- -3 m Determine the…
A:
Step by step
Solved in 5 steps
- 9) what is the weld capacity of the shear connection in kips? (2 decimal places) A992: Fy=50ksi, Fu=65ksiA36: Fy=36ksi, Fu=58ksieffective bolt hole diameter = bolt hole + 1/16"beam properties: tw=0.38 in., bf=7.07 in., tf=0.63 in.Fexx=70ksi. A tie member of a roof truss consists of two angles are connected to either side of a gusset plates and the member is subjected to a working pull “F" as shown in table. Design the weld connection. Assume connections are made in the workshop Angle=ISA 60*40*8 mm Leg connected to gusset plate=60 F=300KN Gusset plate thickness =10mm also DrawThe billboard post support a 5KN dead load as shown. The cantilever beam and the brace is pinnedconnected to the post. Assume that the connections along the cap and the cap plate is adequate, as well asthe gusset plate and the cap plate. Use LRFD design considerations.a.) Determine the ultimate tensile force the brace carries. b.) Determine the adequacy of Connection 1 the bolt where 2- 16mm Ø A325 hex bolt and the plateswhere A36 steel. c.) If the connection at Connection 1 will be a welded connection what will be the adequate thickness ofthe weld. Note that the welds are only applied at the sides of the cap plate. Use electrode 70 for theweld. d.) Determine the adequacy of the connection due to shear and tension in Connection 2 if the bolts were4- 12mm Ø A325 hex bolt.
- Use load and resistance factor design and select a W shape with a nominal depth of 10 inches (a W 10) to resist a dead load of 175 kips and a live load of 175 kips. The connection will be through the flanges with two lines of 11 4 -inch-diameter bolts in each flange, as shown in Figure P3.6-6. Each line contains more than two bolts. The length of the member is 30 feet. Use A588 steal.Select an American Standard Channel shape for the following tensile loads: dead load = 54 kips, live load = 80 kips, and wind load = 75 kips. The connection will be with longitudinal welds. Use an estimated shear lag factor of U = 0.85. (In a practical design, once the member was selected and the connection designed, the value of U would be computed and the member design could be revised if necessary.) The length is 17.5 ft. Use Fy=50 ksi and Fu=65 ksi. a. Use LRFD. b. Use ASD.Determine the capacity of the details shown below. A992: Fy=50ksi, Fu=65ksiA36: Fy=36ksi, Fu=58ksieffective bolt hole diameter = bolt hole + 1/16"beam properties: tw=0.38 in., bf=7.07 in., tf=0.63 in.Fexx=70ksi i) what is the weld capacity of the shear connection in kips? (2 decimal places)
- 20. determine the capacity of the details shown below.A992: Fy=50ksi, Fu=65ksiA36: Fy=36ksi, Fu=58ksieffective bolt hole diameter = bolt hole + 1/16"beam properties: tw=0.38 in., bf=7.07 in., tf=0.63 in.Fexx=70ksit) what is the weld capacity perpedicular to the beam of the flange connection in kips? (2 decimal places)A staggered riveted connection has rivets arranged as shown below. The plate is 400 mm and 12 mm thick with four bolt holes. The diameter of rivet is 34 mm The diameter of the rivet hole is assumed to be 5 mm larger than rivet diameter. Fy = 248 MPa. Fu= 410 MPa, Fv in rivets is 372 MPa. 1. Which of the following gives the distance b so that the net area in section 1 – 2 – 3 – 4 equal to the net area in section 1 – 2 – 4 a. 30.01 mm b. 25.12 mm c. 19.7 mm d. 12.23 mm 2. Which of the following gives the net area using the computed value of b. a. 4622.65 mm² b. 5623.75 mm² c. 3623.64 mm² d. 7652.85 mm² 3. Which of the following gives the maximum tensile force that the connection could carry if the allowable yield stress is Fy/1.67. a. 432.12 kN b. 724.73 kN c. 253.25 kN d. 712.81 kN 4. Which of the following gives the maximum tensile force that the…Determine the capacity of the details shown below.A992: Fy=50ksi, Fu=65ksiA36: Fy=36ksi, Fu=58ksieffective bolt hole diameter = bolt hole + 1/16"beam properties: tw=0.38 in., bf=7.07 in., tf=0.63 in.Fexx=70ksi d) what is the shear yielding capacity of the shear plate of the shear connection in kips? (2 decimal places)
- If the 18 mm plate is connected to two cover plate of 10 mm on top and bottom, what is the capacity of the connection in double shear? Assume that the shear planes pass though the threaded portion. State the condition necessary for these strengths to be available. (Draw the connect first and calculate the capacity). A tie member of a roof truss consists of two angles are connected to either side of a gusset plates and the member is subjected to a working pull “F" as shown in table. Design the weld connection. Assume connections are made in the workshop Angle=ISA 60*40*8 mm Leg connected to gusset plate=60 F=300KN Gusset plate thickness =10mmDetermine the capacity of the details shown below. A992: Fy=50ksi, Fu=65ksiA36: Fy=36ksi, Fu=58ksieffective bolt hole diameter = bolt hole + 1/16"beam properties: tw=0.38 in., bf=7.07 in., tf=0.63 in.Fexx=70ksi g) what is the flexural/local buckling capacity of the shear plate of the shear connection in kips? (2 decimal places)