17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19.A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter12: Lighting Branch Circuit And Small-appliance Circuits For The Kitchen
Section: Chapter Questions
Problem 19R: a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to...
icon
Related questions
Question
17. Where flexible cords are permitted by the code to be permanently connected, it is
permissible to omit
_for such cords.
(a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection
18. Listed or labeled equipment shall be installed, used, or both, in accordance with
(a.) the fob specified (b.) the plans (c.) the instructions given by the authority having
jurisdiction (d.) the instructions included in the listing or labeling 2
19. A grounding electrode connection that is encased in concrete or directly buried
shall
(a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4
bare (d.) not be required to be accessible
20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable
shall all exposed noncurrent carrying metal parts grounded by an insulated
copper equipment grounding conductor not smaller than the supply conductors
and not smaller than
(a.) #16 (c.) # 14 (b.) # 18 (d.) #12|
21. A two pole circuit breaker that may be used for protecting a 3 phase corner
grounded delta circuit shall be marked
(a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.)
480Y/277v
Transcribed Image Text:17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit _for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19. A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT