17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19.A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v
17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19.A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v
Chapter12: Lighting Branch Circuit And Small-appliance Circuits For The Kitchen
Section: Chapter Questions
Problem 19R: a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to...
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT