2. For the following checks you should do with an ohmmeter before connecting power, what results would you expect, and what would a dffering result indicate ? (an example is given in the first row of the table) Ohmmeter test Expected Results Meaning of errant results (explain both, high or low ohms) Power cord blades, R= same as transformer switch closed Open or short circuit on primary side of transformer, or bad primary, between 50 and 3000 transformer. Fuse possibly missing or blown. Bad wiring. Power cord blades, switch open Output terminals, pot fully clockwise Output terminals, pot fully CCW

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.57P: A two-winding single-phase transformer rated 60kVA,240/1200V,60Hz, has an efficiency of 0.96 when...
icon
Related questions
Question
2. For the following checks you should do with an ohmmeter before connecting power, what resuilts would you expect,
and what would a differing result indicate ? (an example is given in the first row of the table)
Ohmmeter test
Expected Results
Meaning of errant results (explain both, high or low ohms)
Power cord blades, R= same as transformer
switch closed
Open or short circuit on primary side of transformer, or bad
primary, between 50 and 3000 transformer. Fuse possibly missing or blown. Bad wiring.
Power cord blades,
switch open
Output terminals,
pot fully clockwise
Output terminals,
pot fully CCW
up
Transformer
secondary
Transcribed Image Text:2. For the following checks you should do with an ohmmeter before connecting power, what resuilts would you expect, and what would a differing result indicate ? (an example is given in the first row of the table) Ohmmeter test Expected Results Meaning of errant results (explain both, high or low ohms) Power cord blades, R= same as transformer switch closed Open or short circuit on primary side of transformer, or bad primary, between 50 and 3000 transformer. Fuse possibly missing or blown. Bad wiring. Power cord blades, switch open Output terminals, pot fully clockwise Output terminals, pot fully CCW up Transformer secondary
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning