22 A consumer is supplied at 380V 3 phase from a 11 kV substation through a 1500 kVA 11kV/380V transformer and a 380V cable as shown in Fig. Q2. An overcurrent relay supplied through a 3000/5 C.T. is installed at the low voltage side of the transformer t protect the cable and the consumer. The fault level of the 11kV substation is 250 MVA The impedance of the transformer and the 380V cable are shown in Fig. Q2. i) Calculate the maximum fault current which the relay will be expected to measure fo any type of fault in the 380V system. 1500 KVA 11KV/380 V 3000/5 MVAse 250 MVA 1x₁-x₂=X₂-5% 2₁-2₂ -0.005 +10.005 Zo-0.01 +10.005 380 V I

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.58P: A single-phase two-winding transformer rated 90MVA,80/120kV is to be connected as an autotransformer...
icon
Related questions
icon
Concept explainers
Question

Plz solve within 30min I vill give definitely upvote and vill give positive feedback thank you sir 

22
A consumer is supplied at 380V 3 phase from a 11 kV substation through a 1500 kVA
11kV/380V transformer and a 380V cable as shown in Fig. Q2. An overcurrent relay
supplied through a 3000/5 C.T. is installed at the low voltage side of the transformer to
protect the cable and the consumer. The fault level of the 11kV substation is 250 MVA.
The impedance of the transformer and the 380V cable are shown in Fig. Q2.
i) Calculate the maximum fault current which the relay will be expected to measure for
any type of fault in the 380V system.
MVAse 250 MVA
II
1x₁-x₂=X₂-5%
Z₁-Z₂-0.005 +10.005
Zo 0.01 +0.005
11 XV
1500 KVA
11 kV/380 V
3000/5
Fig. Q2
380 V
Transcribed Image Text:22 A consumer is supplied at 380V 3 phase from a 11 kV substation through a 1500 kVA 11kV/380V transformer and a 380V cable as shown in Fig. Q2. An overcurrent relay supplied through a 3000/5 C.T. is installed at the low voltage side of the transformer to protect the cable and the consumer. The fault level of the 11kV substation is 250 MVA. The impedance of the transformer and the 380V cable are shown in Fig. Q2. i) Calculate the maximum fault current which the relay will be expected to measure for any type of fault in the 380V system. MVAse 250 MVA II 1x₁-x₂=X₂-5% Z₁-Z₂-0.005 +10.005 Zo 0.01 +0.005 11 XV 1500 KVA 11 kV/380 V 3000/5 Fig. Q2 380 V
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Types of Distribution in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning