3. A 12-pole, 420 V, 10 kW, 50 Hz, three-phase induction motor gave the following test results. Voltage (V) Current (A) 6.7 Power (W) 500 (including 230W Open-circuit test 420 mechanical loss) 980 Locked-rotor test 99 14.0 (a) Calculate the parameters of the per-phase equivalent circuit assuming a star-connected stator winding. (b) Determine the torque, output power, input line current, power factor and efficiency if the machine operates with a slip of 0.03. (c) If the stator winding is actually connected in delta what would be the value of resistance per-phase obtained from direct measurement?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
3. A 12-pole, 420 V, 10 kW, 50 Hz, three-phase induction motor gave the following test results.
Voltage (V)
Power (W)
Current (A)
6.7
Open-circuit test
420
500 (including 230W
mechanical loss)
980
Locked-rotor test
99
14.0
(a) Calculate the parameters of the per-phase equivalent circuit assuming a star-connected
stator winding.
(b) Determine the torque, output power, input line current, power factor and efficiency if
the machine operates with a slip of 0.03.
1
(c) If the stator winding is actually connected in delta what would be the value of resistance
per-phase obtained from direct measurement?
Transcribed Image Text:3. A 12-pole, 420 V, 10 kW, 50 Hz, three-phase induction motor gave the following test results. Voltage (V) Power (W) Current (A) 6.7 Open-circuit test 420 500 (including 230W mechanical loss) 980 Locked-rotor test 99 14.0 (a) Calculate the parameters of the per-phase equivalent circuit assuming a star-connected stator winding. (b) Determine the torque, output power, input line current, power factor and efficiency if the machine operates with a slip of 0.03. 1 (c) If the stator winding is actually connected in delta what would be the value of resistance per-phase obtained from direct measurement?
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Three phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,