4. A special oil is to be used in an absorption tower. The preliminary design of the unit requires the oil to be pumped from an open tank with a 10 ft liquid level above the floor and forced through 150 ft of 3 inches schedule 40 pipe with a ball check valve and 5 elbows into the top of a tower 30 ft above the floor. The operating pressure in the tower is to be 52 psig and the oil requirement is estimated at 50 gpm. The viscosity of the oil 15 cP and its density is 53.5 lbm/ft. Assuming the pumping outfit operates with an overall efficiency of 60%, what horsepower input will be required for the pump motor?

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Topic Video
Question
4. A special oil is to be used in an absorption tower. The preliminary design of the unit
requires the oil to be pumped from an open tank with a 10 ft liquid level above the floor and
forced through 150 ft of 3 inches schedule 40 pipe with a ball check valve and 5 elbows into
the top of a tower 30 ft above the floor. The operating pressure in the tower is to be 52 psig
and the oil requirement is estimated at 50 gpm. The viscosity of the oil 15 cP and its density
is 53.5 Ibm/ft. Assuming the pumping outfit operates with an overall efficiency of 60%, what
horsepower input will be required for the pump motor?
Transcribed Image Text:4. A special oil is to be used in an absorption tower. The preliminary design of the unit requires the oil to be pumped from an open tank with a 10 ft liquid level above the floor and forced through 150 ft of 3 inches schedule 40 pipe with a ball check valve and 5 elbows into the top of a tower 30 ft above the floor. The operating pressure in the tower is to be 52 psig and the oil requirement is estimated at 50 gpm. The viscosity of the oil 15 cP and its density is 53.5 Ibm/ft. Assuming the pumping outfit operates with an overall efficiency of 60%, what horsepower input will be required for the pump motor?
Expert Solution
steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Fluid Statics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY