4. Figure shows a 1-0 system with power source that feeds a 120 kVA 12.47/2.4 kV transformer through a feeder with impedance of 120z60° 2. Load Vane scurce Source Feeder Transformer Load (transmission line) The transformer has been tested to determine its equivalent circuit. The results of the tests are: Open-circuit test Voc = 12.47 kV Ioc = 0.5 A Poc = 900 W Short-circuit test Vsc = 300 V Isc = 50 A Psc = 2.5 kW The load on the transformer is 100 kw at 0.9 p.f. lagging and 2350 v: a. What is the voltage at the power source of the system? b. What is the voltage regulation of the transformer? How efficient is the overall power system? C.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.65P: Reconsider Problem 3.64 with the change that now Tb includes both a transformer of the same turns...
icon
Related questions
icon
Concept explainers
Question
100%
Electrical Engineering
4. Figure shows a 1-0 system with power source that feeds a 120 kVA 12.47/2.4 kV
transformer through a feeder with impedance of 120Z60° 2.
Load
Vource
Source
Feeder
Transfomer
Load
(transmission line)
The transformer has been tested to determine its equivalent circuit. The results of the tests
are:
Open-circuit test
Voc = 12.47 kV
Ioc = 0.5 A
Poc = 900 W
Short-circuit test
Vsc = 300 V
Isc = 50 A
Psc = 2.5 kW
The load on the transformer is 100 kw at 0.9 p.f. lagging and 2350 v:
What is the voltage at the power source of the system?
b. What is the voltage regulation of the transformer?
How efficient is the overall power system?
a.
C.
Transcribed Image Text:Electrical Engineering 4. Figure shows a 1-0 system with power source that feeds a 120 kVA 12.47/2.4 kV transformer through a feeder with impedance of 120Z60° 2. Load Vource Source Feeder Transfomer Load (transmission line) The transformer has been tested to determine its equivalent circuit. The results of the tests are: Open-circuit test Voc = 12.47 kV Ioc = 0.5 A Poc = 900 W Short-circuit test Vsc = 300 V Isc = 50 A Psc = 2.5 kW The load on the transformer is 100 kw at 0.9 p.f. lagging and 2350 v: What is the voltage at the power source of the system? b. What is the voltage regulation of the transformer? How efficient is the overall power system? a. C.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning