4.a. A demountable stud bushing on high-voltage leads eliminates the need for a. an oil stop. b. a gasket. c. a terminal lug. 4.a. A power transformer with standard insulation class of 69 kv will withstand an rms test voltage of A. 140 kv. B. 440 kv. c. 69kv.
Q: A 100 KVA, 2000/200V 1-phase 2-winding Transformer is to be used as an auto transformer for stepping…
A:
Q: A 33 KV substation is to be connected to a 11 KV stepdown substation which is at a distance of 1.5…
A: We have Transmission line which connects 33 KV Sub-Station to 11 KV Substation. This line is 1.5 KM…
Q: a) What is the minimum required transformer rating in kVA? b) By what percentage could the required…
A: It is given that:
Q: A three-phase generator step-up transformer i
A:
Q: Example 1: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results:…
A:
Q: 3.57 A two-winding single-phase transformer rated 60 kVA, 240/1200 V, 60 Hz, has an efficiency of…
A: Transformer : A transformer is a stationary device that transmits electrical energy from one circuit…
Q: b) A single-phase transformer with 10: 1 turns-ratio and rated at 50 kVA, 2400-V/240-V, 50-Hz is…
A: (b): Given in the question: Turns ratio: N1N2=101 Voltage on the primary side is: V1 = 2400V Voltage…
Q: The diagram for a single phase 60 MVA transformer is given below. Convert it to a Step-down…
A: Design the step down autotransformer Single phase transformer have 60MVA 50/100kV Find the all…
Q: Consider that three single-phase transformers are connected as Delta in the primary and Wye in the…
A:
Q: A single phase 500/200 V ,55HZ transformer has an efficiency of 98% at full-load. Determine the…
A: Given input frequency = 55 Hz and no load terminal voltage = 200 volts full load terminal voltage =…
Q: If a 50-turn transformer winding has a 120-V rms applied voltage, and if the peak coupling flux is…
A: Given values are - TurnsN=50Vt=120VoltFluxϕ=20mWb
Q: Impedance of single phase., two winding transformer referred to primary side is 0.1 + j0.6 p.u. The…
A: Given values are - S=1kVAZPP.U=0.1+j0.6V1V2=200400
Q: a) What is the complex power drawn and delivered by the transformer? (b) Draw a per-phase equivalent…
A:
Q: 4.6 A 60 Hz, 75 kVA, 2400/240 V, single-phase transformer is used to step down the voltage of a…
A:
Q: Transformer cooling system in short discussion
A: Transformer A transformer is just a passive electrical device that uses electromagnetic induction…
Q: Using the parameters from the Typical Transformer Values Sheet for a 12.4kV/600V, 100 kVA…
A:
Q: Q2: Draw the circuit diagram, write down the governing equations, and draw the phasor diagram with…
A: Equivalent circuit diagram. Let the turn ratio is a,
Q: With the neat diagram explain the construction and working of Sumpner’s or Back –to-Back test of…
A: Step-1 Construction The Sumpner’s or back-to-back test of a single phase of a transformer…
Q: 1. Consider a three-phase transformer with a rating of 700 MVA and a secondary voltage of 145 kv.…
A:
Q: 10 A three-phase transformer is given. The number of turns of the high voltage winding is N1=850 and…
A: In this question we need to find a type of winding connected in LV side.
Q: The % resistance and the % leakage reactance of a 5 kVA, 220 V / 440 V, 50 Hz, single phase…
A: Given values are - Resistance%=3%ResistancePer unit=0.03Reactance%=4%ReactancePer…
Q: (a) As an Engineer you have been contracted by a power distribution company to investigate the…
A: In the case of the urban area, there is both overheating and overloading. Here the load is more than…
Q: Discuss the following statements briefly 1. The leakage flux is represented by series reactance in…
A: In this question 3 statements given...About transformer leakage reactance, induction motor starting…
Q: 1. A generator connected through a 5-cycle circuit breaker to a transformer is rated 7500 kVA, 6.9…
A: Short circuit current: When a fault occurs at any point and a very high magnitude current flows due…
Q: Iron loss and copper loss in a 25 kVA, 200/200 volt single phase transformer are 400 watts and 500…
A:
Q: 14. In a 50-kVA, 11-kV/400-V, single-phase transformer, the iron and copper losses are 500 W and 600…
A: Given data, KVA rating S = 50 KVA Voltage rating 11 KV / 400 V Iron loss Pi=500 W Copper loss,…
Q: A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent…
A:
Q: In a 1-phase transformer of 20 KVA, 2000/200 volts, the iron and copper losses are 400 W and 500 W…
A:
Q: 1. (a) The diagram for a single phase 60 MVA transformer is given below. Convert it to a Step-down…
A: Given 2-winding transformer details are V1/V2=50/100 kV.S=60 MVA The input and output currents of…
Q: A three phase transformer is used for ancillary services in a thermal power plant. It shows the…
A: transformation ratio = 20/6.6 = 3 for HV side of 18.5 kV, transformation ratio = 18.5/6.6 = 2.8 so,…
Q: Determine the characteristic impedance for a quarter-wave transformer that is used to match a…
A:
Q: ) A single-phase transformer, with primary turns of 500, is delivering full-load of 80 kW at a…
A: We are authorized to answer three sub part at a time, since you have not mentioned which question…
Q: Assume that a 250-kVA distribution transformer is used for single-phase pole mounting. The…
A: Given Data: V1 = 7200 V V2 = 2520 V Zpu = 0.035 pu S = 250 kVA current in HV winding Ihv = 0.7…
Q: Given three phase fullwave with center tapped transformer with 220 Vac source voltage, determine:…
A: Since you have posted a question with multiple sub-parts, we will solve the first three subparts for…
Q: The following test data were obtained from short-circuit and open-circuit tests of a 50-kVA,…
A: Given data Apparent power is S = 50 kVA Voltage is V = 600 V frequency is f = 60 Hz a) Calculating…
Q: Solve for the efficiency at three-eight load at 0.85 power factor of a 10-kVA single phase…
A: As per our guidelines, we are supposed to answer only one question. Kindly repost the question as a…
Q: In the Open-circuit test of the transformer (OC TEST), wattmeter measures 2 kW, in the short-circuit…
A: Given POC =2 KWPSC =200 KW
Q: 4- When a 100-kVA single-phase transformer was tested in this way, the following data were obtained:…
A: The efficiency of a transformer is a measurement of the performance factor of the windings. This…
Q: transformer with a 10:1 ratio and rated at 60kVA, 2200/220V, 60Hz is used to step down the voltage…
A:
Q: A 600 kVA, 1-phase transformer has an efficiency of 92 % both at full-load and half- load at unity…
A: Given, Output kVA rating = 600 kVA Efficiency, η=92 % (both at full-load and half-load) Power…
Q: A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent…
A:
Q: A typical single-phase transformer has a certain value of voltage regulation when connected to the…
A: The problem is related to voltage regulation of transformer. The voltage regulation is positive for…
Q: A single-phase transformer, working at unity power factor has an efficiency of 90 % at both…
A:
Q: In which of the following transformer, the secondary winding is directly connected to primary…
A: Need to find the correct option for the given statement
Q: The primary and secondary windings of a 500-kVA, 11-kV/415-V, single-phase transformer have…
A:
Q: Q1 The oil test condition analysis is the ultimate starting point for any HV transformer assessment.…
A:
Q: A 5000-VA, 480/120-V conventional two-winding transformer is to be used to supply power from a 600-V…
A:
Q: As an Engineer you have been contracted by a power distribution company to investigate the causes of…
A: When the load on the transformer is increased than its maximum capability then it is called…
Q: A 10 MVA three phase load is to be served by a three phase transformer at a line voltage of 13.8 kV.…
A: Transformer is the static device it is used to transfer the electrical power from one terminal to…
Q: 302 j722 םרהj 302 The label values of the single-phase transformer whose electrical equivalent…
A: Given: A 20 KVA, 15400 V/240 V, 50 Hz, single-phase transformer has the following equivalent…
4.a. A demountable stud bushing on high-voltage leads eliminates the need for
a. an oil stop.
b. a gasket.
c. a terminal lug.
4.a. A power transformer with standard insulation class of 69 kv will withstand an rms test voltage of
A. 140 kv.
B. 440 kv.
c. 69kv.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer at the load end of a 2400-volt feeder whose series impedance is (1.0+j2.0) ohm. The equivalent series impedance of the transformer is (1.0+j2.5) ohms referred to the high-voltage (primary) side. The transformer is delivering rated load at a 0.8 power factor lagging and at a rated secondary voltage. Neglecting the transformer exciting current, determine (a) the voltage at the transformer primary terminals, (b) the voltage at the sending end of the feeder, and (c) the real and reactive power delivered to the sending end of the feeder.Three single-phase, two-winding transformers, each rated 450MVA,20kV/288.7kV, with leakage reactance Xeq=0.10perunit, are connected to form a three-phase bank. The high-voltage windings are connected in Y with a solidly grounded neutral. Draw the per-unit equivalent circuit if the low-voltage windings are connected (a) in with American standard phase shift or (b) in Y with an open neutral. Use the transformer ratings as base quantities. Winding resistances and exciting current are neglected.A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a balanced load of three 1, Y-connected resistors. Choosing a base of 90MVA,66kV for the high-voltage side of the three-phase transformer. spify the base for the low-voltage side. Compute the per-unit resistance of the load on the base for the low-voltage side. Also, determine the load resistance in ohms referred to the high-voltage side and the per-unit value on the chosen base.
- Consider a bank of this single-phase two-winding transformers whose high-voltage terminals are connected to a three-phase, 13.8-kV feeder. The low-voltage terminals are connected to a three-phase substation load rated 2.0 MVA and 2.5 kV. Determine the required voltage, current, and MVA ratings of both windings of each transformer, when the high-voltage/low- voltage windings are connected (a) Y-, (b) -Y, (c) Y-Y, and (d) -.A single-phase 100-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer. The load, which is connected to the 240-volt secondary winding, absorbs 60 kVA at 0.8 power factor lagging and is at 230 volts. Assuming an ideal transformer, calculate the following: (a) primary voltage, (b) load impedance, (c) load impedance referred to the primary, and (d) the real and reactive power supplied to the primary winding.Consider Figure 3.4. For an ideal phase-shifting transformer, the imda nce is unchanged when it is referred from one side to the other. (a) True (b) False
- Consider the oneline diagram shown in Figure 3.40. The three-phase transformer bank is made up of three identical single-phase transformers, each specified by X1=0.24 (on the low-voltage side), negligible resistance and magnetizing current, and turns ratio =N2/N1=10. The transformer bank is delivering 100 MW at 0.8 p.f. lagging to a substation bus whose voltage is 230 kV. (a) Determine the primary current magnitude, primary voltage (line-to-line) magnitude, and the three-phase complex power supplied by the generator. Choose the line-to-neutral voltage at the bus, Va as the reference Account for the phase shift, and assume positive-sequence operation. (b) Find the phase shift between the primary and secondary voltages.A 23/230-kV step-up transformer feeds a three-phase transmission line, which in turn supplies a 150-MVA,0.8 lagging power factor load through a step-down 230/23-kV transformer. The impedance of the line and transformers at 230kVis18+j60. Determine the tap setting for each transformer to maintain the voltage at the load at 23 kV.Reconsider Problem 3.64 with the change that now Tb includes both a transformer of the same turns ratio as Ta and a regulating transformer with a 4 phase shift. On the base of Ta, the impedance of the two comp onents of Tb is jO.1 per unit. Determine the complex power in per unit transmitted to the load through each transformer. Comment on how the transformers share the real and reactive pors.
- A single-phase l0-kVA,2300/230-volt,60-Hz two-winding distribution transformer is connected as an autotransformer to step up the voltage from 2300 to 2530 volts (a) Draw a schematic diagram of this arrangement, showing all voltages and currents when delivering full load at rated voltage. (b) Find the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the rated values as a two-winding transformer. How much of this kVA rating is transformed by magnetic induction? (C) The following data are obtained from tests carried out on the transformer when it is connected as a two-winding transformer: Open-circuit test with the low-voltage terminals excited: Applied voltage =230V, input current =0.45A, input power =70W. Short-circuit test with the high-voltage terminals excited: Applied voltage =120, input current =4.5A, input power =240W. Based on the data, compute the efficiency of the autotransformer corresponding to full load, rated voltage, and 0.8 power factor lagging. Comment on why the efficiency is higher as an autotransformer than as a two-winding transformer.The ratings of a three-phase three-winding transformer are Primary(1): Y connected 66kV,15MVA Secondary (2): Y connected, 13.2kV,10MVA Tertiary (3): A connected, 2.3kV,5MVA Neglecting winding resistances and exciting current, the per-unit leakage reactances are X12=0.08 on a 15-MVA,66-kV base X13=0.10 on a 15-MVA,66-kV base X23=0.09 on a 10-MVA,13.2-kV base (a) Determine the per-unit reactances X1,X2,X3 of the equivalent circuit on a 15-MVA,66-kV base at the primary terminals. (b) Purely resistive loads of 7.5 MW at 13.2 kV and 5 MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per- unit impedance diagram, showing the per-unit impedances on a 15-MVA,66-kV base at the primary terminals.A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters: Resistance of the 2400-V winding: R1=0.75 Resistance of the 240-V winding: R2=0.0075 Leakage reactance of the 2400-V winding: X1=1.0 Leakage reactance of the 240-V winding: X2=0.01 Exciting admittance on the 240-V side =0.003j0.02S (a) Draw the equivalent circuit referred to the high-voltage side of the transformer. (b) Draw the equivalent circuit referred to the low-voltage side of the transformer. Show the numerical values of impedances on the equivalent circuits.