5-20. A welded built-up 16 in. x 16 in. box column in the bottom story of a highrise building is made up of 3 in. thick steel plates (A992 Grade 50). Assuming the column has an unbraced length of 14 ft., determine the following: a. The gross area, A, of the column. b. The moments of inertia about the x-x and y-y axes, I and I,, respectively, c. The radii of gyration about the x-x and y-y axes, r, and r, respectively.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
5-20. A welded built-up 16 in. x 16 in. box column in the bottom story of a highrise building is
made up of 3 in. thick steel plates (A992 Grade 50). Assuming the column has an unbraced
length of 14 ft., determine the following:
a. The gross area, A,, of the column.
b. The moments of inertia about the x-x and y-y axes, I and I,, respectively,
c. The radii of gyration about the x-x and y-y axes, r, and r,, respectively.
d. Using the LRFD method, determine the axial compression strength in kips for the
column.
e. Using the column load tables, select a wide flange or I-shaped column of A992 Grade
50 steel that has the same axial compression load capacity as the box column and com-
pare the weights of both sections. Which of the column section (built-up box section or
I-shape) is more economical?
Transcribed Image Text:5-20. A welded built-up 16 in. x 16 in. box column in the bottom story of a highrise building is made up of 3 in. thick steel plates (A992 Grade 50). Assuming the column has an unbraced length of 14 ft., determine the following: a. The gross area, A,, of the column. b. The moments of inertia about the x-x and y-y axes, I and I,, respectively, c. The radii of gyration about the x-x and y-y axes, r, and r,, respectively. d. Using the LRFD method, determine the axial compression strength in kips for the column. e. Using the column load tables, select a wide flange or I-shaped column of A992 Grade 50 steel that has the same axial compression load capacity as the box column and com- pare the weights of both sections. Which of the column section (built-up box section or I-shape) is more economical?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Compression members
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning