6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor? A. The conduit is terminated in listed fittings. B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less. C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet. D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes. 7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding. C. the end of the shortest branch circuit. D. the first connected IT cabinet. 8. What is another term for ground loops? A. Electrical noise B. Objectionable current C. Dirty ground D. Low-level circulating current 9. If an overcurrent device is rated for 60 amps three-phase, then the copper equipment grounding conductor should be sized A. AWG 8. B. AWG 6. C. AWG 10. D. AWG 4.

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter25: Television, Telephone, And Low-voltage Signal Systems
Section25.1: Television Circuit
Problem 10R: It is generally understood that grounding and bonding together all metal parts of an electrical...
icon
Related questions
Question
100%

6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor?

A. The conduit is terminated in listed fittings.
B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated

at 20 amperes or less.
C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet.

D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes.

7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at

A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.
C. the end of the shortest branch circuit.
D. the first connected IT cabinet.

8. What is another term for ground loops? A. Electrical noise
B. Objectionable current
C. Dirty ground

D. Low-level circulating current

9. If an overcurrent device is rated for 60 amps three-phase, then the copper equipment grounding conductor should be sized

A. AWG 8. B. AWG 6. C. AWG 10. D. AWG 4.

10. Which of the following statements about auxiliary grounding electrodes is true? A. They're often specified as a design requirement.
B. They must be bonded to the grounding electrode system for the building or structure.
C. It's not permissible to connect them to the equipment grounding conductors.

D. They're required by the National Electrical Code.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Dielectric breakdown
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning