6.7 A refrigerated room, used for product cooling, is being maintained at the desired temperature using an evaporator temperature of 0°C and condenser pressure of 900 kPa with an R-134a vapor-compression refrigeration system. The condenser is a countercurrent tubular heat exchanger with water entering at 25°C and leaving at 35°C. Evaluate the following for a refrigeration load of 5 tons: a. The rate of heat exchange at the condenser b. The compressor power requirement at 80% efficiency c. The coefficient of performance for the system d. The heat transfer surface area in the condenser when the overall heat transfer coefficient is 500 W/m2 °C e. The flow rate of water through the condenser

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.17P
icon
Related questions
Question
6.7 A refrigerated room, used for product cooling, is being
maintained at the desired temperature using an evaporator
temperature of 0°C and condenser pressure of 900 kPa with
an R-134a vapor-compression refrigeration system. The
condenser is a countercurrent tubular heat exchanger with
water entering at 25°C and leaving at 35°C. Evaluate the
following for a refrigeration load of 5 tons:
a. The rate of heat exchange at the condenser
b. The compressor power requirement at 80% efficiency
c. The coefficient of performance for the system
d. The heat transfer surface area in the condenser when the
overall heat transfer coefficient is 500 W/m² °C
e. The flow rate of water through the condenser
Transcribed Image Text:6.7 A refrigerated room, used for product cooling, is being maintained at the desired temperature using an evaporator temperature of 0°C and condenser pressure of 900 kPa with an R-134a vapor-compression refrigeration system. The condenser is a countercurrent tubular heat exchanger with water entering at 25°C and leaving at 35°C. Evaluate the following for a refrigeration load of 5 tons: a. The rate of heat exchange at the condenser b. The compressor power requirement at 80% efficiency c. The coefficient of performance for the system d. The heat transfer surface area in the condenser when the overall heat transfer coefficient is 500 W/m² °C e. The flow rate of water through the condenser
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 7 steps with 1 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning