Construct didactic sketches, showing the operating principles of both heat pumps and refrigeration systems Estimate the reversible COP values, if the low and high medium temperature are as for the evaporator and condenser.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter6: Forced Convection Over Exterior Surfaces
Section: Chapter Questions
Problem 6.8P
icon
Related questions
Question

please anwser task 2

Mollier or Pressure/enthalpy charts is another alternative to obtain a quick and initial performance estimation of
refrigeration/heat pump cycles used in heating, ventilation and air-conditioning (HVAC) system. Your role in a
company that provide design and installation services for air -conditioning (AC) system is provide preliminary
performance estimation. You have been given the following design specifications:
The system design specifications are as follows:
Refrigerant HFC-134a as the working fluid
Ideal cycle operation condition is assumed
Cycle is operated at high pressure line of 0.8 MPa
Cycle is operated at low temperature line of – 10° C
- Flow rate is 0.05 kg/sec
Your manager asked you to make use of pressure/enthalpy chart provided for HFC-134a refrigerant in the
Appendix.A to estimate the following:
Task.1
1. Construct TS-plot.
2. Refrigeration effect (RE), heat of compression (HOC), and heat of rejection (HOR) and their
corresponding rate/power values.
3. Estimate the COPR and COPHP
4. Determine the low-pressure line value.
Task.2
1. Construct didactic sketches, showing the operating principles of both heat pumps and refrigeration
systems
2. Estimate the reversible COP values, if the low and high medium temperature are as for the evaporator
and condenser.
Transcribed Image Text:Mollier or Pressure/enthalpy charts is another alternative to obtain a quick and initial performance estimation of refrigeration/heat pump cycles used in heating, ventilation and air-conditioning (HVAC) system. Your role in a company that provide design and installation services for air -conditioning (AC) system is provide preliminary performance estimation. You have been given the following design specifications: The system design specifications are as follows: Refrigerant HFC-134a as the working fluid Ideal cycle operation condition is assumed Cycle is operated at high pressure line of 0.8 MPa Cycle is operated at low temperature line of – 10° C - Flow rate is 0.05 kg/sec Your manager asked you to make use of pressure/enthalpy chart provided for HFC-134a refrigerant in the Appendix.A to estimate the following: Task.1 1. Construct TS-plot. 2. Refrigeration effect (RE), heat of compression (HOC), and heat of rejection (HOR) and their corresponding rate/power values. 3. Estimate the COPR and COPHP 4. Determine the low-pressure line value. Task.2 1. Construct didactic sketches, showing the operating principles of both heat pumps and refrigeration systems 2. Estimate the reversible COP values, if the low and high medium temperature are as for the evaporator and condenser.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Types of Loading
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning