A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging. The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5 times the effect of the armature leakage reactance wherein the later is 0.046 N per phase, find (a) the phase voltage which would be generated at the load (b) What no-load open circuit phase voltage is required to circulate full-load current at short-circuit condition with no-change made at the speed and field current? (c) What is the alternators terminal phase voltage at shorted load condition? Explain and justify your answer in one(1) sentence. Use la as the reference phasor.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.21P: An industrial plant consisting primarily of induction motor loads absorbs 500 kW at 0.6 power factor...
icon
Related questions
icon
Concept explainers
Question
A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging.
The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5
times the effect of the armature leakage reactance wherein the later is 0.046 n per
phase, find
(a) the phase voltage which would be generated at the load
(b) What no-load open circuit phase voltage is required to circulate full-load current at
short-circuit condition with no-change made at the speed and field current?
(c) What is the alternators terminal phase voltage at shorted load condition? Explain
and justify your answer in one(1) sentence.
Use la as the reference phasor.
Transcribed Image Text:A 100KVA, 220V, star connected alternator is loaded at full-load and at 60% pf lagging. The effective AC resistance per phase is 0.014110. If the synchronous reactance is 4.5 times the effect of the armature leakage reactance wherein the later is 0.046 n per phase, find (a) the phase voltage which would be generated at the load (b) What no-load open circuit phase voltage is required to circulate full-load current at short-circuit condition with no-change made at the speed and field current? (c) What is the alternators terminal phase voltage at shorted load condition? Explain and justify your answer in one(1) sentence. Use la as the reference phasor.
Expert Solution
steps

Step by step

Solved in 5 steps with 1 images

Blurred answer
Knowledge Booster
Synchronous Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning