A 2-) L1= 6 m L2= 10 m C L3= 15 m S1= 3x6 mm? S2= 3x4 mm S3= 3x2,5 mm? N= 10 kW N= 5 kW N= 7 kW In the figure, the length of the conductor cross-section between the ports and the receiverforces are given. The operating voltage is 380 volts and the conductors are planned to pass through the air, 3% of the voltage drop will not be allowed to pass. (The power coefficient is coso=0.8). (The specific conductivity coefficient for copper is 56) a -) find the voltage drops belween the ports separately. b-) according to the Total voltage drop, find out if the selected sections are suitable. c-) find the currents for each conductor separately. d-) according to the currents you find, write down whether the selected sections are appropriate and why. E-) find the main network Current between A and D.

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter18: Lighting Branch Circuit, Receptacle Circuits For Workshop
Section: Chapter Questions
Problem 20R: a. When more than three current-carrying conductors are installed in one raceway, their allowable...
icon
Related questions
Question
A
2-)
L1= 6 m
L2= 10 m
3= 15 m
S1= 3x6 mm-
S2= 3x4 mm
53= 3x2,5 mm
N= 10 kW
N= 5 kW
N= 7 kW
In the figure, the length of the conductor cross-section between the ports and the receiverforces are
given. The operating voltage is 380 volts and the conductors are planned to pass through the air, 3%
of the voltage drop will not be allowed to pass. (The power coefficient is coso-0.8). (The specific
conductivity coefficient for copper is 56)
a-) find the voltage drops belween the ports separately.
b-) according to the Total voltage drop, find out if the selected sections are suitable.
C-) find the currents for each conductor separately.
d-) according to the currents you find, write down whether the selected sections are appropriate and
why.
E-) find the main network Current between A and D.
Sozcak407
Aramak için buraya yazın
Transcribed Image Text:A 2-) L1= 6 m L2= 10 m 3= 15 m S1= 3x6 mm- S2= 3x4 mm 53= 3x2,5 mm N= 10 kW N= 5 kW N= 7 kW In the figure, the length of the conductor cross-section between the ports and the receiverforces are given. The operating voltage is 380 volts and the conductors are planned to pass through the air, 3% of the voltage drop will not be allowed to pass. (The power coefficient is coso-0.8). (The specific conductivity coefficient for copper is 56) a-) find the voltage drops belween the ports separately. b-) according to the Total voltage drop, find out if the selected sections are suitable. C-) find the currents for each conductor separately. d-) according to the currents you find, write down whether the selected sections are appropriate and why. E-) find the main network Current between A and D. Sozcak407 Aramak için buraya yazın
Expert Solution
steps

Step by step

Solved in 6 steps

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT