(a) A three-phase transposed single line is composed of one Aluminium conductor steel- reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i). The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of 1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with horizontal spacing of 14m as measured from the center of the bundles as shown in Figure Q4(a)(ii). a b. D12 = 11 m- D23 = 11 m- D13 = 22 m- (i) 45 D12 14 m D23 14 m- D13 = 28 m (ii) gure Q4(a): Conductor layout of three phase transmission line (i) single conductor (iüi) three-bundles conductors (i) Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839 cm. The spacing between the conductors in the bundle is 45 cm. Compare between the individual and three-conductor bundled for three phase transmission line and include the justification of the parameter changes based on the percentage change in the inductance.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.26P
icon
Related questions
Question
I need the answer as soon as possible
(a) A three-phase transposed single line is composed of one Aluminium conductor steel-
reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's
conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i).
The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of
1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the
specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with
horizontal spacing of 14m as measured from the center of the bundles as shown in
Figure Q4(a)(ii).
a
D12 = 11 m
D23
= 11 m
D13 = 22 m-
(i)
O,0
45
D12 = 14 m-
D23 14 m-
D13
28 m
(ii)
Figure Q4(a): Conductor layout of three phase transmission line (i) single conductor (ii)
three-bundles conductors
(i)
Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839
cm. The spacing between the conductors in the bundle is 45 cm. Compare
between the individual and three-conductor bundled for three phase transmission
line and include the justification of the parameter changes based on the
percentage change in the inductance.
Transcribed Image Text:(a) A three-phase transposed single line is composed of one Aluminium conductor steel- reinforced (ACSR) with the specification of 1,431,000-cmil and 47/7-Bobolink's conductor type per phase with horizontal spacing of 11 m as shown in Figure Q4(a)(i). The conductors have a diameter of 3.625cm and geometric mean radius (GMR) of 1.439cm. The link is to be replaced by a three-conductor bundled of ACSR with the specification of 477,000-cmil and 26/7-Hawk's conductor type per phase with horizontal spacing of 14m as measured from the center of the bundles as shown in Figure Q4(a)(ii). a D12 = 11 m D23 = 11 m D13 = 22 m- (i) O,0 45 D12 = 14 m- D23 14 m- D13 28 m (ii) Figure Q4(a): Conductor layout of three phase transmission line (i) single conductor (ii) three-bundles conductors (i) Three-conductor's bundles have a diameter of 2.1793 cm and GMR of 0.8839 cm. The spacing between the conductors in the bundle is 45 cm. Compare between the individual and three-conductor bundled for three phase transmission line and include the justification of the parameter changes based on the percentage change in the inductance.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning