A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine Pu, when e=192.5mm, eccentricity is measured parallel to the long direction, fc'=27.6 MPa and fy=414 Mpa. A 1275.25 kN B 1532.23kN 1038.8 kN D 901.23 kN A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine the eccentricity that corresponds to a nominal axial load of 810.08 kN, eccentricity is measured parallel to the long direction, fc"=27.6 MPa and fy=414 Mpa. 285mm B 260mm 385mm D 300mm

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

PLEASE HELP.

 

ANSWER SHOULD BE ON THE CHOICES

A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine Pu, when
e=192.5mm, eccentricity is measured parallel to the long direction, f'-27.6 MPa and fy=414 Mpa.
A
1275.25 kN
В
1532.23kN
1038.8 kN
D
901.23 kN
A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine the
eccentricity that corresponds to a nominal axial load of 810.08 kN, eccentricity is measured parallel to the long direction, fc=27.6 MPa and fy=414 Mpa.
285mm
B
260mm
385mm
D
300mm
Transcribed Image Text:A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine Pu, when e=192.5mm, eccentricity is measured parallel to the long direction, f'-27.6 MPa and fy=414 Mpa. A 1275.25 kN В 1532.23kN 1038.8 kN D 901.23 kN A column 385mm x 320mm, is reinforced with 6-28mm bar, three bars distributed equally in short dimension, effective cover is 57.75mm. Determine the eccentricity that corresponds to a nominal axial load of 810.08 kN, eccentricity is measured parallel to the long direction, fc=27.6 MPa and fy=414 Mpa. 285mm B 260mm 385mm D 300mm
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Knowledge Booster
Solar energy
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning