A long-shunt compound generator supplies 22 kW at a terminal voltage of 220 V. The resistance of the armature, the shunt field and the series field are respectively 0.05 ohm, 110 ohms and 0.06 ohm. If the overall efficiency of the above load is 88%, find iron a friction losses.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.21P: An industrial plant consisting primarily of induction motor loads absorbs 500 kW at 0.6 power factor...
icon
Related questions
icon
Concept explainers
Question
1
A long-shunt compound generator supplies 22 kW at a
terminal voltage of 220 V. The resistance of the
armature, the shunt field and the series field are
respectively 0.05 ohm, 110 ohms and 0.06 ohm. If the
overall efficiency of the above load is 88%, find iron a
friction losses.
Transcribed Image Text:A long-shunt compound generator supplies 22 kW at a terminal voltage of 220 V. The resistance of the armature, the shunt field and the series field are respectively 0.05 ohm, 110 ohms and 0.06 ohm. If the overall efficiency of the above load is 88%, find iron a friction losses.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Synchronous Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning