A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively. In both cycles, the refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine: a. the mass flow rate of the refrigerant through the upper cycle Ib/s b. the rate of heat removal from the refrigerated space TR c. the rate of heat removal from the refrigeration system BTU/hr d. the actual total compressor power input, Hp e. the actual COP of this system

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter22: Condensers
Section: Chapter Questions
Problem 7RQ: When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be...
icon
Related questions
Question
Fill in the blanks:
A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia
with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat
exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively In both cycles, the refrigerant is a
saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor
is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine:
a. the mass flow rate of the refrigerant through the upper cycle
Ib/s
b. the rate of heat removal from the refrigerated space
TR
c. the rate of heat removal from the refrigeration system
BTU/hr
d. the actual total compressor power input,
Hp
e. the actual COP of this system
Transcribed Image Text:Fill in the blanks: A two-stage cascade refrigeration system operates between the condenser pressure of 440 psia and evaporator pressure of 120 psia with R-410a as the working fluid. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counter-flow heat exchanger where the pressure in the upper and lower cycles are 220 psia and 230 psia, respectively In both cycles, the refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet, and the isentropic efficiency of the compressor is 80%. If the mass flow rate of the refrigerant through the lower cycle is 0.3 lb/s, determine: a. the mass flow rate of the refrigerant through the upper cycle Ib/s b. the rate of heat removal from the refrigerated space TR c. the rate of heat removal from the refrigeration system BTU/hr d. the actual total compressor power input, Hp e. the actual COP of this system
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning