An air conditioned room is maintained at 25 °C dry bulb and 50% relative humidi

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
i need the answer quickly
An air conditioned room is maintained at 25 °C dry bulb and 50% relative humidity. The room sensible ar
Jatent heat loads are 11.5 kW and 7.5 kW, respectively. The outside design conditions are 35 °C dry bulb an
28 °C wb. Returm air from the room is mixed with the outside air before entering the cooling coil in the rat
of 4:1 and returm air is also mixed after the cooling coil in the same ratio of 4:1. The cooling coil has th
bypass factor of 0.1, and the apparatus dew point temperature is is to be 8 °C. The air is reheated befor
supplying to the conditioned room. Sketch the process on the psychrometrie chart and find the followings:
a) The conditions of air leaving the coil.
b) The supply air conditions to the room.
e) The cooling coil capacity.
d) The quantity of fresh air supplied in kg/s.
e) The mass flow rate of moisture removed in the coil.
Transcribed Image Text:An air conditioned room is maintained at 25 °C dry bulb and 50% relative humidity. The room sensible ar Jatent heat loads are 11.5 kW and 7.5 kW, respectively. The outside design conditions are 35 °C dry bulb an 28 °C wb. Returm air from the room is mixed with the outside air before entering the cooling coil in the rat of 4:1 and returm air is also mixed after the cooling coil in the same ratio of 4:1. The cooling coil has th bypass factor of 0.1, and the apparatus dew point temperature is is to be 8 °C. The air is reheated befor supplying to the conditioned room. Sketch the process on the psychrometrie chart and find the followings: a) The conditions of air leaving the coil. b) The supply air conditions to the room. e) The cooling coil capacity. d) The quantity of fresh air supplied in kg/s. e) The mass flow rate of moisture removed in the coil.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Dimensional Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY