An electric radiator is required to dissipate 1 kW when connected to a 230 V supply. If the coils of the radiator are of wire 0.5 mm in diameter having resistivity of 60 µ-cm, calculate the necessary length of the wire.

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter2: Basic Electricity
Section: Chapter Questions
Problem 34RQ: What is the Btu/hour output of an electric heater rated at 15 kilowatts? a. 51.15 Btu/hour b. 51,150...
icon
Related questions
Question
11. An electric radiator is required to dissipate 1 kW when connected to a 230 V supply. If the coils of
the radiator are of wire 0.5 mm in diameter having resistivity of 60 μ-cm, calculate the necessary
length of the wire.
[1732 cm]
Transcribed Image Text:11. An electric radiator is required to dissipate 1 kW when connected to a 230 V supply. If the coils of the radiator are of wire 0.5 mm in diameter having resistivity of 60 μ-cm, calculate the necessary length of the wire. [1732 cm]
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Electric heating unit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning