An ideal multi-pressure refrigeration system consists of two Compressors serving one 60 Tons Evaporator at -20°C. The system uses two-stage compression with intercooling and flash Tank. A pressure reducer valve reduces the condenser pressure to intercooler pressure. The condensing temperature is 47•C. The refrigerant is R22. Calculate (a) enthalpy leaving evaporator (b) enthalpy leaving LP compressor (c) enthalpy entering HP compressor

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter28: Special Refrigeration Applications
Section: Chapter Questions
Problem 14RQ: Truck trailers with their own refrigeration systems, which are transported on railway cars, are...
icon
Related questions
Question
pressure
reducer valve
saturated liquid
wet vapor
expansion valve
condenser
1812.1 kPa, T 47°C
Qc
3 saturated vapor
Intercooler
Flash Tank
0.4 MPa
saturated liquid
8 wet vapor
Evaporator
244,83 kPa,
Isa-20C
Q₂. 60 tons
superheated vapor.
L.P.
COMP.
H.P.
COMP.
superheated vapor
W₂
saturated vapor
WHP
Transcribed Image Text:pressure reducer valve saturated liquid wet vapor expansion valve condenser 1812.1 kPa, T 47°C Qc 3 saturated vapor Intercooler Flash Tank 0.4 MPa saturated liquid 8 wet vapor Evaporator 244,83 kPa, Isa-20C Q₂. 60 tons superheated vapor. L.P. COMP. H.P. COMP. superheated vapor W₂ saturated vapor WHP
QUIZ 2
An ideal multi-pressure refrigeration system consists of two Compressors serving one 60 Tons Evaporator at -20°C. The
system uses two-stage compression with intercooling and flash Tank. A pressure reducer valve reduces the condenser
pressure to intercooler pressure. The condensing temperature is 47°C. The refrigerant is R22.
Calculate
(a) enthalpy leaving evaporator
(b) enthalpy leaving LP compressor
(c) enthalpy entering HP compressor
Transcribed Image Text:QUIZ 2 An ideal multi-pressure refrigeration system consists of two Compressors serving one 60 Tons Evaporator at -20°C. The system uses two-stage compression with intercooling and flash Tank. A pressure reducer valve reduces the condenser pressure to intercooler pressure. The condensing temperature is 47°C. The refrigerant is R22. Calculate (a) enthalpy leaving evaporator (b) enthalpy leaving LP compressor (c) enthalpy entering HP compressor
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning