Asiacell|ASIACELL 3G 2G zain IQ BartlebySolutions.. 1 • Q1: During the separation of transformer core losses experiment: 1. Why should always keep the ratio of V/F constant? 2. Ifthe transformer is operated at rated frequency but at voltage lower than rated value, how do you expect the following quantities to change? And why? i. Hysteresis loss ii. Eddy current loss ii. No-load current

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.27P: A three-phase transformer is rated 1000MVA,220Y/22kV. The Y-equivalent short-circuit impedance,...
icon
Related questions
Question
Asiacell|ASIACELL
3G
2G
zain 1Q
BartlebySolutions..
Q1: During the separation of transformer core losses experiment:
1. Why should always keep the ratio of V/F constant?
2. Ifthe transformer is operated at rated frequency but at voltage lower than rated value, how
do you expect the following quantities to change? And why?
i.
Hysteresis loss
ii.
Eddy current loss
iii.
No-load current
3. If the ratio of V/F has been kept constant and the observed value of hysteresis loss at rated
frequency of 50 Hz is 18 W, the measured value of core losses is 35 W, Find the total core
losses at the frequency of 60 Hz.
إضافة وصف. . .
Transcribed Image Text:Asiacell|ASIACELL 3G 2G zain 1Q BartlebySolutions.. Q1: During the separation of transformer core losses experiment: 1. Why should always keep the ratio of V/F constant? 2. Ifthe transformer is operated at rated frequency but at voltage lower than rated value, how do you expect the following quantities to change? And why? i. Hysteresis loss ii. Eddy current loss iii. No-load current 3. If the ratio of V/F has been kept constant and the observed value of hysteresis loss at rated frequency of 50 Hz is 18 W, the measured value of core losses is 35 W, Find the total core losses at the frequency of 60 Hz. إضافة وصف. . .
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L