b) TNB steam power plant in Cameron Highlands operates on reheat Rankine cycle and has power net output of 45 MW. Steam enters the turbine at a MPa and b °C and it is cooled in the condenser at a pressure of c kPa by running cooling water from the Bertam River through the tubes of condenser. Steam enters both stages of the turbine at 500°C. If the moisture content of the steam at the exit of the low-pressure turbine is not to exceed 10 percent, show the cycle on a T-s diagram and determine; i. The pressure at which reheating takes place, ii. The thermal efficiency of the cycle and iii. Please justify how does the thermal efficiency of the cycle if the temperature to low turbine is increase to 600°C?

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter47: High-pressure, Low-pressure, And Absorption Chilled-water Systems
Section: Chapter Questions
Problem 13RQ: The subcooling temperature in a condenser can be measured by taking the difference between the A....
icon
Related questions
Question

a=12 mpa

b=500 c

c=13 kpa

b) TNB steam power plant in Cameron Highlands operates on reheat Rankine cycle and
has power net output of 45 MW. Steam enters the turbine at a MPa and b °C and it is
cooled in the condenser at a pressure of c kPa by running cooling water from the Bertam
River through the tubes of condenser. Steam enters both stages of the turbine at 500°C.
If the moisture content of the steam at the exit of the low-pressure turbine is not to exceed
10 percent, show the cycle on a T-s diagram and determine;
i.
The pressure at which reheating takes place,
ii.
The thermal efficiency of the cycle and
Please justify how does the thermal efficiency of the cycle if the temperature to
low turbine is increase to 600°C?
Transcribed Image Text:b) TNB steam power plant in Cameron Highlands operates on reheat Rankine cycle and has power net output of 45 MW. Steam enters the turbine at a MPa and b °C and it is cooled in the condenser at a pressure of c kPa by running cooling water from the Bertam River through the tubes of condenser. Steam enters both stages of the turbine at 500°C. If the moisture content of the steam at the exit of the low-pressure turbine is not to exceed 10 percent, show the cycle on a T-s diagram and determine; i. The pressure at which reheating takes place, ii. The thermal efficiency of the cycle and Please justify how does the thermal efficiency of the cycle if the temperature to low turbine is increase to 600°C?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Axial Load
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning