b. As mentioned above, the heat rate of th kJ/kWh). The utilized coal contains 80 perce kJ/kg. Let us assume 70 percent of the CO₂ is Considering the total capacity and capacity f emissions of the plant in kg given that the m 12.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

just explain (d )

b. As mentioned above, the heat rate of the power plant is 9000 Btu/kWh (i.e., 9495
kJ/kWh). The utilized coal contains 80 percent carbon and has a heating value of 30,000
kJ/kg. Let us assume 70 percent of the CO₂ is filtered before being sent to the environment.
Considering the total capacity and capacity factor of the plant, determine the annual CO₂
emissions of the plant in kg given that the molecular weight of CO₂ over that of C is 44 /
12.
c. Considering that the plant should pay the penalty factor of $0.1/kg.CO₂ for the CO₂
emission, recalculate the minimum electricity price that should be offered to the power
grid.
d. Suppose the power grid is not interested in the new offered price by the plant. Does it
make sense if the plant operator decreases the CF of the plant to address this issue? Why
/ Why not?
Transcribed Image Text:b. As mentioned above, the heat rate of the power plant is 9000 Btu/kWh (i.e., 9495 kJ/kWh). The utilized coal contains 80 percent carbon and has a heating value of 30,000 kJ/kg. Let us assume 70 percent of the CO₂ is filtered before being sent to the environment. Considering the total capacity and capacity factor of the plant, determine the annual CO₂ emissions of the plant in kg given that the molecular weight of CO₂ over that of C is 44 / 12. c. Considering that the plant should pay the penalty factor of $0.1/kg.CO₂ for the CO₂ emission, recalculate the minimum electricity price that should be offered to the power grid. d. Suppose the power grid is not interested in the new offered price by the plant. Does it make sense if the plant operator decreases the CF of the plant to address this issue? Why / Why not?
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,