what is the answer??! help!

In medicine, it is often important to monitor the blood flow in certain areas of the body. However, the movement of blood is
difficult to monitor directly. Instead, some medical devices use the Hall effect, taking advantage of the fact that the blood flowing
through a vein contains a considerable number of free ions.
B
+-
h
+
+
+
Model the vein in a patient's arm to be of rectangular cross section, as shown in the figure, with a width w = 4.00 mm and
height h = 3.85 mm. The entire section of the vein is immersed in a constant magnetic field of B = 0.0955 T, pointing
horizontally and parallel to the width. A medical device constantly monitors the resulting Hall voltage.
Suppose that medical precautions mandate that the speed of the blood flow for this particular component of the body should
never drop below 21.50 cm/s. At what minimum Hall voltage VH, in millivolts, should the medical device be designed to trigger
an alarm to the medical staff?
VH =
mV
Transcribed Image Text:In medicine, it is often important to monitor the blood flow in certain areas of the body. However, the movement of blood is difficult to monitor directly. Instead, some medical devices use the Hall effect, taking advantage of the fact that the blood flowing through a vein contains a considerable number of free ions. B +- h + + + Model the vein in a patient's arm to be of rectangular cross section, as shown in the figure, with a width w = 4.00 mm and height h = 3.85 mm. The entire section of the vein is immersed in a constant magnetic field of B = 0.0955 T, pointing horizontally and parallel to the width. A medical device constantly monitors the resulting Hall voltage. Suppose that medical precautions mandate that the speed of the blood flow for this particular component of the body should never drop below 21.50 cm/s. At what minimum Hall voltage VH, in millivolts, should the medical device be designed to trigger an alarm to the medical staff? VH = mV
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Relativistic speed and time
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Physics for Scientists and Engineers: Foundations…
Physics for Scientists and Engineers: Foundations…
Physics
ISBN:
9781133939146
Author:
Katz, Debora M.
Publisher:
Cengage Learning
Physics for Scientists and Engineers
Physics for Scientists and Engineers
Physics
ISBN:
9781337553278
Author:
Raymond A. Serway, John W. Jewett
Publisher:
Cengage Learning
Physics for Scientists and Engineers with Modern …
Physics for Scientists and Engineers with Modern …
Physics
ISBN:
9781337553292
Author:
Raymond A. Serway, John W. Jewett
Publisher:
Cengage Learning
Physics for Scientists and Engineers, Technology …
Physics for Scientists and Engineers, Technology …
Physics
ISBN:
9781305116399
Author:
Raymond A. Serway, John W. Jewett
Publisher:
Cengage Learning
Principles of Physics: A Calculus-Based Text
Principles of Physics: A Calculus-Based Text
Physics
ISBN:
9781133104261
Author:
Raymond A. Serway, John W. Jewett
Publisher:
Cengage Learning