Example 26.14. In a 120 V compound generator, the resistances of the armature, shunt and series windings are 0.06 Q, 25 Q and 0.04 Q respectively. The load current is 100 A at 120 V. Find the induced e.m.f. and the armature current when the machine is connected as (i) long-shunt and as (ii) short-shunt. How will the ampere-turns of the series field be changed in (i) if a diverter of 0.1 ohm be connected in parallel with the series winding ? Neglect brush contact drop and ignore m ronction (Eloct Machines AMIE SoC R. 1002)

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter11: Transient Stability
Section: Chapter Questions
Problem 11.3P
icon
Related questions
Question
Example 26.14. In a 120 V compound generator, the resistances of the armature, shunt and
series windings are 0.06 Q, 25 and 0.04 Q respectively. The load current is 100 A at 120 V. Find
the induced e.m.f. and the armature current when the machine is connected as (i) long-shunt and as
(ii) short-shunt. How will the ampere-turns of the series field be changed in (i) if a diverter of 0.1
ohm be connected in parallel with the series winding ? Neglect brush contact drop and ignore
(Elect. Machines AMIE Sec. B, 1992)
armature reaction.
Transcribed Image Text:Example 26.14. In a 120 V compound generator, the resistances of the armature, shunt and series windings are 0.06 Q, 25 and 0.04 Q respectively. The load current is 100 A at 120 V. Find the induced e.m.f. and the armature current when the machine is connected as (i) long-shunt and as (ii) short-shunt. How will the ampere-turns of the series field be changed in (i) if a diverter of 0.1 ohm be connected in parallel with the series winding ? Neglect brush contact drop and ignore (Elect. Machines AMIE Sec. B, 1992) armature reaction.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning