Example 3 A short-shunt compound generator delivers a load current of 30 A at 220 V. It has armature, series and shunt field resistances of o.o5, 0.3 and 200 (ohm) respectively. Calculate the generated emf and the armature current. Allow 1.0 V per brush for contact drop.
Example 3 A short-shunt compound generator delivers a load current of 30 A at 220 V. It has armature, series and shunt field resistances of o.o5, 0.3 and 200 (ohm) respectively. Calculate the generated emf and the armature current. Allow 1.0 V per brush for contact drop.
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.45P
Related questions
Question
A short-shunt compound generator delivers a load current of 30 A at 220 V. It has armature, series and shunt field resistances of 0.05, 0.3 and 200 (ohm) respectively. Calculate the generated emf and the armature current. Allow 1.0 V per brush for contact drop.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning