In column chromatography, the following statements are true except-* The stationary phase is held in a narrow tube through which the mobile phase is forced under pressure The effectiveness of the chromatographic column in separating two solutes depends in part on the relative rates at which the two species are eluted The stationary phase is supported in a flat plate or in interstices where the mobile phase moves through by capillary action or under the influence of gravity Predict the order of elution of the following components if a normal phase column and hexane:methylene chloride mobile phase was used in the separation. (A.) Propanone (B.) Propanoic acid (C.) Methyl ethanoate BCA ABC ACB The following are true for the observed tailings and fronting in a chromatogram, except- Fronting and tailing leads to a good separation and reproducible elution times Tailing is observed when the tail appears to the right of the chromatogram and front is steepened while fronting is observed when the tail is steepened Common cause of fronting and tailing is a distribution constant that varies with concentration
In column chromatography, the following statements are true except-* The stationary phase is held in a narrow tube through which the mobile phase is forced under pressure The effectiveness of the chromatographic column in separating two solutes depends in part on the relative rates at which the two species are eluted The stationary phase is supported in a flat plate or in interstices where the mobile phase moves through by capillary action or under the influence of gravity Predict the order of elution of the following components if a normal phase column and hexane:methylene chloride mobile phase was used in the separation. (A.) Propanone (B.) Propanoic acid (C.) Methyl ethanoate BCA ABC ACB The following are true for the observed tailings and fronting in a chromatogram, except- Fronting and tailing leads to a good separation and reproducible elution times Tailing is observed when the tail appears to the right of the chromatogram and front is steepened while fronting is observed when the tail is steepened Common cause of fronting and tailing is a distribution constant that varies with concentration
Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter33: Automated Methods Of Analysis
Section: Chapter Questions
Problem 33.8QAP
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT