INPUTS Maximum Fuel Temperature Bar Pressure Surge Pool Water Level BINARY VALUE 1 0 1 0 1 0 or DESCRIPTION T≥ 240 °C T < 240 °C P> 3.4 bar/ P < 4.1 bar 3.4 bar ≤ P ≤ 4.1 bar W> 3 ft from normal level W≤ 3 ft from normal level A warning signal (S = 1) will be produced when any of the following occurs: Either (a) T≥ 240 °C or (b) T≥ 240 °C and P > 3.4 bar/ P < 4.1 bar (c) T≥ 240 °C and W> 3 ft from normal level (d) T≥ 240 °C and P> 3.4 bar/ P < 4.1 bar and W> 3 ft from normal level CREATE THE LOGIC CIRCUIT SHOWING ALL THE POSSIBLE SITUATIONS. SHOW THE TRUTH TABLE.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.27P
icon
Related questions
Question

Asap 

INPUTS
Maximum Fuel Temperature
Bar Pressure Surge
Pool Water Level
BINARY VALUE
1
0
1
0
1
0
or
DESCRIPTION
T≥ 240 °C
T< 240 °C
P> 3.4 bar/ P < 4.1 bar
3.4 bar ≤ P ≤ 4.1 bar
W> 3 ft from normal level
W ≤ 3 ft from normal level
A warning signal (S = 1) will be produced when any of the following occurs:
Either
(a) T≥ 240 °C
or
(b) T≥ 240 °C and P > 3.4 bar/ P < 4.1 bar
(c) T≥ 240 °C and W> 3 ft from normal level
(d) T≥240 °C and P > 3.4 bar/ P < 4.1 bar and W> 3 ft from normal level
CREATE THE LOGIC CIRCUIT SHOWING ALL THE POSSIBLE SITUATIONS. SHOW THE TRUTH TABLE.
Transcribed Image Text:INPUTS Maximum Fuel Temperature Bar Pressure Surge Pool Water Level BINARY VALUE 1 0 1 0 1 0 or DESCRIPTION T≥ 240 °C T< 240 °C P> 3.4 bar/ P < 4.1 bar 3.4 bar ≤ P ≤ 4.1 bar W> 3 ft from normal level W ≤ 3 ft from normal level A warning signal (S = 1) will be produced when any of the following occurs: Either (a) T≥ 240 °C or (b) T≥ 240 °C and P > 3.4 bar/ P < 4.1 bar (c) T≥ 240 °C and W> 3 ft from normal level (d) T≥240 °C and P > 3.4 bar/ P < 4.1 bar and W> 3 ft from normal level CREATE THE LOGIC CIRCUIT SHOWING ALL THE POSSIBLE SITUATIONS. SHOW THE TRUTH TABLE.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Analysis of Multiple Order System and Steady State Error
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning