Investigate passive Cooling methods and strategies in design and construction of at least three outstanding traditional buildings and vernacular architecture in Woodlake, California
Q: Give the Indian Air Quality Standards (SPM, SO2, NOx, CO) for Residential, Industrial and Sensitive…
A: Air quality also called Ambient air quality, is the quality and condition of air in residential,…
Q: Sanitary Engineering laboratory the test " Relative Humidity of Air" discuss
A:
Q: Total cooling load; Moisture removed per hour; Minimum diameter of the fresh air duct so that the…
A:
Q: Discuss three ways to remove water from the air in an air distribution system.
A: Explanation- Although it is hard to completely eliminate moisture from your air compressors, you can…
Q: A mass of air is at temperature of 30 °C and is having relative humidity of 75 %. Determine the…
A: Given: Temperature, T = 30°C Relative humidity, RH = 75%
Q: Compare two pipe, one pipe and single stack drainage systems of house plumbing. State two relative…
A: Solution: As per the question asked
Q: 5-Most supermarkets use air-conditioning systems designed primarily to control temperature, and…
A: Most supermarkets use air-conditioning systems designed primarily to control temperature because the…
Q: briefly explain why there is flow observed in the sewer when there is no rainfal
A: INTRODUCTION: Sewer system is designed to transport the waste water . runoff water from the…
Q: Highlight different produced pollutants produced from laboratories, offices, ward and other areas of…
A: There different types of pollutants produces from laboratories, office, ward and the office wards…
Q: Determine the required fire flow for a three storeys wood building covering 750 m which connects…
A: Given: The 3 storey building covering area is 750 m2. The 5 storey building covering area is 900 m2.
Q: State the purpose of air quality monitoring.
A: Brief concept- Air quality monitoring- It means to know about the different pollutants present in…
Q: a. At 1:00 P.M., a thermometer reading 70°F is taken outside where the air temperature is - 10°F…
A: Using Newtons…
Q: What are the factors affecting evaporation, measurement of evaporation and evapo-transpiration? All…
A: THERE ARE 4 FACTORS TO AFFECT EVAPORATION :- 1. TEMPERATURE2. SURFACE AREA 3. HUMIDITY 4. WIND SPEED…
Q: Q.3: Building requires to maintain different temperature settings. What are most common cooling…
A: Building cooling systems are in high demand in tropical countries. Especially where the high…
Q: Net radiation at the Laguna Lake is 175 W/m2 at noon on February 14th. Air temperature is 28.0°C,…
A: Given: The net radiation is 175 W/m2. The air temperature is 28oC. The relative humidity is 72%. The…
Q: Which of the following does not affect the demand for cooling in a given space? Select one:
A: The demand for cooling in a given space directly depends upon the energy consumption.
Q: Discuss the systems and equipment available for cooling systems in large buildings.
A: It can be necessary to provide cooling to buildings during warm weather or where there are…
Q: Climatic condition data in Mountain Province for the months of July, August and September are…
A:
Q: Determine the required diameter (in cm) at the downstream end of a conical diffuser such that the…
A: Let 1 denotes upstream and 2 denotes downstream D1=10cm
Q: Building requires to maintain different temperature settings. What are most common cooling system…
A: Focal cooling frameworks are the most energy-proficient approach to cooling a few city blocks…
Q: By means of equations and illustrations, explain clearly the difference between constant rate…
A: Constant rate filtration - The resistance offered to the flow is constant or approximately more or…
Q: Discuss the three positions in which thermal insulation may be installed in a low-slope roof, and…
A: Solution: Low slope roofs are basically flat with the value of slope less than 17 percent. It is…
Q: With given data mc = 35g , mc + w = 520 g , mc + d = 472 g , calculate total evaporable moisture,…
A: Given data- mc = 35g mc + w = 520 gmc + d = 472 gTo Find-total evaporable moisture, surface…
Q: n Schedule 40 steel pipe that will carry 0.8 ft3 /s of water at 50°F downhill and limit the total…
A: According to given data lean Schedule 40 steel pipe that will carry 0.8 ft3 /s of water at 50°F…
Q: As a building services engineer, you are given a task by the management to design a new mechanical…
A: Ventilation system : The deliberate injection of external air into a space is known as ventilation.…
Q: Determine the required FRP duct diameter assuming a duct velocity (Uduct) of 2,000 ft/min, and an…
A: Given: The duct velocity is 2000 ft/min. The actual air emission rate is 15300 ft3/min.
Q: Please solve both question and detail solution and not Copypaste otherwise down vote
A: True Hvac System design must be prepared by a licensed professional engineer beacause they used…
Q: Below what humidity for 95°F air will we not have to worry about sweating asthe air flows past 72°F…
A: Given:- air T=95oF=350C air flows at Dew temp Tdew=720F=22.230C To find:- humidity
Q: Elucidate the kind of VAV HVAC control system that is most suitable in Architectural constraints of…
A: VAV(variable air volume ) in HVAC control system is used for heating, air conditioning and…
Q: Compare the performance of hoods A and B. Calculate the capture velocity at a distance of 3.5 feet.…
A: step 1-
Q: If the air quality standard for CO is given as 9.0 ppmv, express this standard as percent by volume…
A: Solution: We know that, 1 ppmv=1 part of pollutant106 parts of…
Q: The moisture removed from a material is 250 lb/hr and change of humidity ratio in dryer is 0.0175.…
A: To determine the fan capacity for a given dryer. Given, Change in humidity ratio = 0.0175 Rate of…
Q: To help minimize any tendency for fine particles to migrate through the filter, and to drain as much…
A: Holes or slots are created in soil holding buildings such as retaining walls, underpasses, wing…
Q: Why would one use a "low pass filter" when designing a water filltration system?
A: Low pass filters are used to eliminate noise in a circuit. When a sound is passed through a low pass…
Q: A rectangular lot was measured using a 50-m steel tape at 30 oC. If the recorded length and width of…
A: To Find :- error in the area of the rectangular lot measured.
Q: Assess the potential reduction of sound transmission through insulation and attenuation strategies,…
A: The noise spectrum from aircraft noise sources contains more low-frequency energy; The exterior…
Q: Based on the materials of the course, building loads for which an HVAC system must compensale…
A: 1. There are various types of loads to be considered for HVAC system on buildings HVAC - Heat…
Q: A well-mixed, insulated water storage tank is to be maintained at internal temperature 60°C. The…
A: For any material, it's insulation capacity is defined by thermal resistance value which can be…
Q: 1. A mass of air is having temperature of 26.9 oC. The Relative humidity of this mass of air is 71…
A: Temperature of air (T)= 26.9 Degree Celsius Relative humidity (Rh) = 71 % Determine : Saturation…
Q: Central air conditioning system is the main mechanical ventilation system that used in most of the…
A: Introduction : Air is cooled in a central place and transferred to and from rooms using one or more…
Q: Propose THREE (3) strategies for the control of volatile organic compounds (VOCS) in indoor air.
A: Volatile organic compounds (VOCs) are the chemicals which are found in various products which are…
Q: Q5: Imagine that you do not want the CO2 concentration to exceed 766 ppm. What is the minimum…
A: Cin=Cout+GNKQ Cin= 766 ppm Cout= 400 ppm G= 0.005 N= 4 people K=1000000
Q: A 100-year storm occurs in Northern Nevada. You wish to find the precipitation and infiltration rate…
A: Answer Given data Area of the lake = 10 ft2 Evaporation for the pond = 48 in = 4812 Evaporation…
Q: A rectangular lot was measured using a 50-m steel tape at 30 oC. If the recorded length and width of…
A:
Q: Which statement is TRUE about displaceme ventilation in UFAD systems? air from the floor is prone to…
A: In UFAD, mixing is enhanced resulting in even air temperature.
Q: e factors (structures) that
A: There factores that contribute to the building's heating and cooling loss; 1.Gaps These are defined…
Step by step
Solved in 3 steps
- What is passive cooling of buildings? explain various passive cooling technologies with the help diagrams. Which technologies are suitable for UAE climate? Hint: UAE climate is very hot sometimes 45 degrees and 30% humidity.A two-story building of volume of 540 m3 has an effective air leakage area of 510 cm2. The outdoor and indoor design temperatures for winter conditions are í10°C and 20°C respectively. The average design wind speed is 7msí1. The house is sheltered by other houses across the street. Estimate (i) the air infiltration rate, and (ii) the air exchange rate per hour.A rectangular lot was measured using a 50-m steel tape at 30 oC. If the recorded length and width of the lot are 197.56m and 105.63m respectively. Determine the Error in the area, if the coefficient of thermal expansion is 0.0000116/ oC and standard temperature of the tape is 25 oC. detailed solution pls thank you
- Determine the required FRP duct diameter assuming a duct velocity (Uduct) of 2,000 ft/min, and an actual air emission rate (Qa) of 15,300 acfm.b.) calculate the outside air flow for the restaurant dining area where cold air is supplied from the ceiling, lit/secFor an air-conditioning system, the outdoor and indoor design dry bulb temperatures are 45°C and 25°C respectively. The space to be air-conditioned Is 20m x 30m x 5m and infiltration is estimated to be one alr are 1.2 (kg of dry air)/m³ and 1.02 kJ/(kg of dry air) °C, then the sensible heat load due to Infiltration is, nearly
- Discuss the three positions in which thermal insulation may be installed in a low-slope roof, and the advantages and disadvantages of each.Which of the following does not affect the demand for cooling in a given space? Select one: a. Number of occupants in the given space b. Positioning of the room in the house c. Direction where the building is facing d. Cooling capacity of the cooling systemCalculate the fan power if the average pressure drop m 0.6 in, H2O, and the fan/motor efficiency is 70%. An ESP must treat 800,000 aefra with 99% efficiency.
- A rectangular lot was measured using a 50-m steel tape at 30 oC. If the recorded length and width of the lot are 197.56m and 105.63m respectively. Determine the Error in the area, if the coefficient of thermal expansion is 0.0000116/ oC and standard temperature of the tape is 25 oC.A department store plans to construct a one-story building with a rectangular planform. The building is required to have a floor area of 10,000 f2 and a height of 15 ft. It is proposed to use brick walls on three sides and a glass wall on the fourth side. Use the Lagrange multipliers to find the dimensions of the building to minimize the heat loss, assuming that the relative heat losses per unit surface area for the roof, brick wall, glass wall, and floor are in the proportion 3:2:7:1A cold-storage warehouse is to be constructed of a number of individual rooms that are maintained at various temperatures. The walls of one room are constructed of 4 inches thick masonry on the outside of 0.5 inches thick plywood on the side. Sandwiched between the masonry and plywood is glass fiber insulation that is 3.5 inches thick. The inside-wall temperature is to be maintained at −10°F and the outside-wall temperature is 70°F. As a first step in sizing the required cooling unit, determine the heat flow the wall on a per-square-foot basis.