Problem #2: An 8-pole simplex wave connected dc generator has 1000 armature conductors and fluX per pole of 0.035 Wb. At what speed must it be driven to generate 500 V?
Q: 2. A 4-pole generator has a lap-wound armature with 50 slots with 16 conductors per slot. The useful…
A: No. of pole p= 4 no. of parallel path A= P= 4 No. of slot = 50 16 conductor 1 slot Total no. of…
Q: A 4 pole d.c. generator has 1000 armature conductors and generates 250 V on open circuit when…
A:
Q: A 4 pole generator with wave wound armature has 52 slots each having 22 conductors. The flux per…
A:
Q: Q2: A 6-pole, wave wound generator has 48 slots with 20 conductors in each. the flux per pole is…
A:
Q: A 4-pole generator having wave wound armature winding has 50 slots, each slots containing 20…
A:
Q: An 4-pole d.c. generator has 290 armature conductors, and a useful flux of 40 mWb per pole. What…
A: DC generator The emf equation of DC generator is E=Poles X Number of conductors X Flux X Speed/ 60 X…
Q: An 10-pole d.c. generator has 440 armature conductors, and a useful flux of 36 mWb per pole. What…
A: as solve below
Q: the lap wound armature of a six pole generator has600 active conductors. The speed is 1000rpm. The…
A: Given in the question: Number of poles, P = 6 Number of conductors, Z = 600 Speed of the machine, N…
Q: b- The armature of an 8 poles DC shunt generator is wave-connected and generates 216 v when running…
A:
Q: How many armature conductors are there in a duplex lap-wound generator given the following…
A: According to question: In duplex lap winding A = 2P Where A = No of parallel paths. P = No of…
Q: A 4-pole generator has a lap-wound armature with 50 slots with 16 conductors per slot. The useful…
A:
Q: An 10-pole d.c. generator has 385 armature conductors, and a useful flux of 24 mWb per pole. What…
A:
Q: An 8-pole d.c. generator has 410 armature conductors, and a useful flux of 46 mWb per pole. What…
A:
Q: A 4 pole lap wound DC generator has the following details: Flux = 0.7 web/pole, speed = 900 rpm,…
A: Given, a lap wound DC generator having Number of poles, P = 4 Lap wound, so number of parallel path,…
Q: An 6-pole d.c. generator has 365 armature conductors, and a useful flux of 28 mWb per pole. What…
A: Dc generator convert mechanical energy in to electrical energy. It works on principle of Faraday's…
Q: 1. Which of the following is/are a reason for the drop in terminal voltage of a separately excited…
A: There is an typing error is question B2 Please correct it It's not latninated it is laminated
Q: 6. A 500-kW, 500-V, 10 pole d.c. generator has a lap-wound armature with 800 conductors. Calculate…
A: given number of conductors Z= 800 pole arc/ pole pitch = 0.75 or 75% no of poles P = 10 due to lap…
Q: A 6 pole generator with wave wound armature has 50 slots each having 24 conductors. The flux per…
A: Given, Generator with wave wound, So number of parallel path, A= 2 Number of Pole, P= 6 Slots= 50,…
Q: A lap connected 6 pole DC generator has an armature conductors of 500 and is driven at 600 rpm. If…
A: The solution for the given DC generator is solved below and attached.
Q: A 6 pole generator with wave wound armature has 54 slots each having 28 conductors. The flux per…
A:
Q: A 2-circuit armature of a 4-pole generator has 51 slots, each slot containing 20 1500 r p.m,…
A: Given values are - 2-CircuitPoleP=4SlotsS=51Number of conductors per…
Q: A 4 pole generator with wave wound armature has 52 slots each having 26 conductors. The flux per…
A: In this question we need to find a speed of wave wound genrator when induced voltage is 225 V and…
Q: A d.c. shunt-wound generator running at 10rps generates a voltage of 150V at a certain value of…
A:
Q: A 4-pole dc generator has 150 conductors being wound simplex wave of its armature. If the flux per…
A: GivenNumber of poles P=4Number of conductors Z=150Number of parallel paths A=2Flux ϕ=25…
Q: An 10-pole d.c. generator has 585 armature conductors, and a useful flux of 46 mWb per pole. What…
A:
Q: A 4-pole DC generator runs at 650 rpm and generates an EMF of 200 V. The armature is wave wound and…
A: Given a DC generator with, Rated emf, E = 200 V Total number of pole, P = 4 Speed, N = 650 rpm Wave…
Q: An 6-pole d.c. generator has 550 armature conductors, and a useful flux of 40 mWb per pole. What…
A:
Q: An 6-pole d.c. generator has 475 armature conductors, and a useful flux of 16 mWb per pole. What…
A: We need to find out generated emf for given machine .
Q: An 8-pole d.c. generator has 290 armature conductors, and a useful flux of 10 mWb per pole. What…
A:
Q: A 4-pole generator has a lap-wound armature with 50 slots with 16 conductors per slot. The useful…
A: Given data, Number of pole =4 Number of parallel path A=P=4 Number of slot =50 Total number of…
Q: An 6-pole d.c. generator has 445 armature conductors, and a useful flux of 46 mWb per pole. What…
A: In this question, Find the value of generated emf and speed if winding is connected to Wave.
Q: Ruestion 4 What is exciter in a DC shunt generator? How the emf induced in armature of generator can…
A:
Q: 1-A 4 pole shunt generator with wave-wound armature has 41 slots, each having 12 conductors. The…
A: As per the guidelines of Bartleby we have to solve 1st question for rest of the question we request…
Q: A 4 pole generator, having wave wound armature winding has 55 slots, each slot containing 19…
A: Given values are - Wave windingNumber of polesP=4Number of slotsS=55Number of conductor in one…
Q: An 6-pole d.c. generator has 290 armature conductors, and a useful flux of 12 mWb per pole What will…
A: In this question , we will find speeds for dc machine..
Q: 1-A four pole generator having wave-wound armature winding has 51 slots, each slot containing 20…
A: This question belongs to electrical machine . It is based on the concept of induced voltage .
Q: (1) An 16-pole generator has 1000 armature conductors and has a useful flux per pole of 130mWb. What…
A: As per the guidelines of Bartleby we supposed to answer first question only for remaining questions…
Q: A 6 pole generator with wave wound armature has 58 slots each having 24 conductors. The flux per…
A: Given: P=6A=2Slot=58Con/slot=24ϕ=0.01 WbE=235 V
Q: a dc shunt generator has a generated emf 240v and a constant value of 8, if it is running at 1500…
A: we need to find out flux.
Q: Q2/ An eight poles DC shunt generator supplies a load of 12.5 ohm at 250 V. its armature carries…
A: We need to equivalent circuit and governing equations
Q: A 6 pole DC wave wound generator has 41 armature conductors with Flux per pole is 26 mWb and the…
A:
Q: In a 4 pole DC shunt generator with a shunt field resistance of 100 ohms and an armature resistance…
A:
Q: An 6-pole d.c. generator has 515 armature conductors, and a useful flux of 10 mWb per pole. What…
A: We need to find out generated emf and speed for motor .
Q: a 6-pole dc generator has 500 armature conductors, and a useful flux of 0.05Wb per pole. What will…
A: Given that P=6ϕ=0.05 Wb/poleN=1200 rpmA=P=6 (lap winding)Z=500 case 1: For Lap winding For DC…
Q: The following questions refer to a 6-pole DC generator has a simplex lap-wound armature containing…
A:
Q: A 6 pole generator with wave wound armature has 58 slots each having 20 conductors. The flux per…
A:
Q: A four pole generator having wave-wound armature winding has 51 slots, each slot containing 20…
A:
Q: An 6-pole d.c generator has 300 armature conductors, and a useful flux of 14 mWb per pole. What will…
A: em.f. generated =Flux×speed×Number of armature conductors60×Number of polesNumber of parallel paths.…
Q: A 4 pole generator with wave wound armature has 56 slots each having 28 conductors. The flux per…
A:
Step by step
Solved in 2 steps with 1 images
- An 4-pole d.c generator has 435 armature conductors, and a useful flux of 20mWb per pole. What will be the e.m.f generated if it is lap-connected and runs at 1320rpm? What must be the speed at which it is to be driven produce the same e.m.f if it is wave-wound?A 6 pole DC wave wound generator has 41 armature conductors with Flux per pole is 26 mWb and the e.m.f generated is 79 V, then the speed of machine is ?a circuit armature of a 4 pole generator has 51 slots , each slot containing 20 conductors . What will be the voltage generated in the machine when driven at 1500r.p.m. , assuming the useful flux per pole to be 0.7*10^-2
- A lap connected 6 pole DC generator has an armature conductors of 500 and is driven at 600 rpm. If the flux per pole is 15 mWb, then the generated e.m.f is,؟ 250 V 225 V 75 V 100 VA lap connected 6 pole DC generator has an armature conductors of 500 and is driven at 600 rpm. If the flux per pole is 15 mWb, then the generated e.m.f is, Choose correct answer : A) 75 V B) 100 V C) 250 V D) 225 VAn 8-pole d.c. generator has 290 armature conductors, and a useful flux of 10 mWb per pole. What will be the e.m.f. generated if it is lap-connected and runs at 1280 rpm? What must be the speed at which it is to be driven produce the same e.m.f. if it is wave-wound?
- An 6-pole d.c. generator has 475 armature conductors, and a useful flux of 16 mWb per pole. What will be the e.m.f. generated if it is lap-connected and runs at 1290 rpm? What must be the speed at which it is to be driven produce the same e.m.f. if it is wave-wound? Eg Answer for part 1 SpeedA 6 pole generator with wave wound armature has 50 slots each having 24 conductors. The flux per pole is 0.01 Wb. (i) At what speed must the armatur rotate to give an induced EMF of 230V is, (ii) What will be the voltage developed, if the winding is lap connected and the armature rotates at the same speed is?A 4 pole generator with wave wound armature has 50 slots each having 28 conductors. The flux per pole is 0.01 Wb. (i) At what speed must the armature rotate to give an induced EMF of 225V is, (ii) What will be the voltage developed, if the winding is lap connected and the armature rotates at the same speed is,
- A 4 pole dc generator runs at 750 rpm and generates an emf of 240 V. The armature is wave wound and has 792 conductors. If the total flux from each pole is 0.0145 Wb, If leakage coefficient is given as the ratio of the total flux/pole to the working flux per pole, find its value.How many armature conductors are there in a duplex lap-wound generator given the following information: Total Flux = 2.73 x 106, Poles = 4, Rpm = 1200, Eg = 240How many armature conductors are there in a duplex lap-wound generator given the following information: Total Flux = 2.73 x 106 Maxwell, Poles = 4, Rpm = 1200, Eg = 240