Problem 4.9: A 60-Hz synchronous generator rated 30 MVA at 0.90 power factor has the no-load frequency of 61 Hz. Determine (1) the prime mover speed regulation, (2) generator frequency regulation, and (3) generator frequency droop rate.
Q: Draw voltage phasor diagrams for different load cases of salient pole synchronous generators and…
A: Here it is asking to draw the voltage phasor diagrams for different load cases of salient pole…
Q: A 3 phase 4MVA, 12 kV star connected synchronous generator has Zs= 0.8+J30 ohm. Using circle diagram…
A: 3φ synchronous generator,4MVA,12kVZs=0.8+j30 ΩZs=R+jX ΩR=0.8Ω
Q: what The parameters of the synchronous generators?
A: Following are the parameters for the synchronous generators- per phase stator winding electrical…
Q: (a) Give comparison between salient pole and non-salient pole type synchronous generator.
A: Note :- We’ll answer the first question since the exact one wasn’t specified. Please submit a new…
Q: Is the parallel operation of shunt generators stable if their characteristics are not identical?…
A: Parallel operation of DC generators is required to meet the extra load demand. It is always…
Q: Question 4:What would happen if the series properties of the DC compound generato were as much as…
A: NOTE: “Since you have asked multiple question, we will solve the first question for you. If you want…
Q: Consider the two-bus power system shown in Figure P6.2. The marginal cost of production of the…
A: Since you have asked more than one question, I will answer the first question and all its subparts.…
Q: Discuss the double field revolving theory and discuss the equivalent circuit diagram of single phase…
A: Single phase Induction Motor are also known as Fractional kW motors. It is commonly used in…
Q: A 1000 kVA, 6.6 kV, 3-phase star connected cylindrical pole synchronous generator has a synchronous…
A: Given values are - S=1000kVAVt=6.6kVXs=20ohmUnity power factor.cosϕ=1
Q: (2)A 20 MVA, 3-phase, star-connected, 50HZ, salient pole synchronous generator with X; =1 pu, X =…
A:
Q: How does field distortion affect commutation ? ( DC GENERATOR QUESTION)
A: The armature reaction cause the alteration with the main field and cause the demagnetization or the…
Q: 1. Using vector diagram show and briefly explain the effect of supply voltage changes on a…
A: The armature current Ia in a DC motor is calculated by multiplying the difference between V and Eb…
Q: Explain the concept of load transfer between the DC generators operating in parallel using load…
A: to explain the concept of load transfer between the DC generators operating in parallel using load…
Q: Write and explain the parallel connection conditions of synchronous generators?
A:
Q: 5- Why should the terminal voltage drop more in the case of shunt generator than in the case of…
A: NOTE :- As per out rule we’ll answer the first question since the exact one wasn’t specified. Please…
Q: 4- Is there a great difference between long and short shunt compound generator, show that?
A: Compound Generator: The generator which have both shunt fields and series fields is called the…
Q: The effect of the capacitor on the operation of the asynchronous machine as a generator what? Please…
A: The asynchronous machine acting as a generator is a type of induction machine. The rotor of such…
Q: A short shunt cumulative compound dc generator supplies 6kW at 235V. The Shunt field resistance,…
A:
Q: Write a report on test Zero Power factor characteristics and loss measurement of Synchronous…
A: consider the given question;
Q: Q3: A synchronous generator with peak generated voltage Vg which is connected to a lighting arrester…
A: Equivalent per phase diagram Apply KVL in loop 1)
Q: Why the power factor of three-phase induction motor low at no-load and increase as applied load…
A: Power factor is define the cosine of power factor angle. So Why the power factor of three-phase…
Q: 2. For which reasons its not possible to develop rated voltage of d.c shunt generator, both in…
A: It is not possible to develop a rated voltage in dc shunt generator because of the commutation.…
Q: Discuss in detail about the steady state performance synchronous machine operation, when connected…
A: The steady-state characteristics of a synchronous motor : It can be represented by phasor diagrams…
Q: The torque angle of synchronous machine operating from a constant voltage bus, is usually defined as…
A: the torque angle of synchronous machine is operated from a constant voltage bus, is usually defined…
Q: Questicn 1: Why do we keep the speed of ihe synchronous generator constant at no-load? What happens…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: A 90-MVA 69.3-KV, three-phase synchronous generator has a synchronous reactance of 11 Ohms/phase and…
A: In this question we need to find a power delivered by genrator, armature current and power factor
Q: The breadth factor for 3rd harmonic emf of a 3 phase, 4 pole, synchronous machine having 36 stator…
A: Given a 3-phase synchronous machine having, 3rd harmonic, r =3 Number of pole, P = 4 Number of slots…
Q: What is displacement power factor and true power factor? Describe the significance of these power…
A: Here we discuss about two important terms used in power electronics i.e. displacement power factor…
Q: Explain Synchronous Generator Features, Uses, and Control Methods Using Pictures and Graphics
A: Synchronous generator - The alternator, also known as a synchronous generator, converts mechanical…
Q: Questions:- 1. What is the basic different between the internal characteristics and the external…
A: As per our policy I have to do the first one only. Internal Characteristics The internal…
Q: What is the Difference between (Cumulative compound & Differential compound DC generator)??
A:
Q: 4. Why is the fall in the terminal voltage for the external characteristic greater in shunt…
A: The electrical machines can be motor or generator. The generators convert the mechanical energy into…
Q: 7. What is the nature of the generator-load frequency characteristics? 8. What is the effect of a…
A: Load-frequency characteristics: Under equilibrium conditions, but with equivalent primary control…
Q: Explain compound DC generator, also describe its types and terminal characteristics of compound DC…
A: As we know that generator is a electrical device which is use to convert mechanical energy to…
Q: power syste unit quantities instead of actual values. Give the advantages of using such a system.…
A: (a) Advantages Of Per-unit System- It gives a clear idea of relative magnitudes of various…
Q: Compared between three_ phase induction generator and synchronous them at impedance field and EMF…
A:
Q: The condition for maximum efficiency of DC generator is given by - Choose
A:
Q: Four similar synchronous generators are sharing equally the feed to a load of 1 pu referred to the…
A: To find the correct option from the given statements
Q: Explain Compound DC. :- generator, types also describe its and terminal characteristics of compound…
A:
Q: 1- Static synchronous compensator (STATCOM) for powe factor improvement. 2- What is penalty factor?…
A: Static synchronous compensator (STATCOM) STATCOM is a reactive power compensation device connected…
Q: Explain how active load and reactive load sharing is achieved between synchronously connected…
A: Load sharing: Load sharing is the dividing the total load(i.e. Kw and Kvar) in proportion to the…
Q: 3) Why Ego is not equal to zero at If=0 in separately excited do generator?
A: Need to find Eg0 is not equal to zero at If=0 in separately excited DC generator why
Q: What is the reason for drop in Generator’s Terminal voltage, from No load to Full load?
A:
Q: report about Simulation of Modeling Theory of Frequency Synchronous Generator Using Pl Controller
A: Synchronous generators (also called Alternators) are broadly used in power plants to send mass…
Q: Draw voltage phasor diagrams for different load cases of salient synchronous generators and derive…
A: Synchronous generators are used for power generation. The power factor shows the phase relation…
Q: -Why is the fall in the terminal voltage for the external chara, greater shunt generator than in…
A: The explanation is as follows.
Step by step
Solved in 2 steps with 2 images
- (vi) Explain the concept of load transfer between the DC generators operating in parallel using load –voltage characteristics.Write and explain the parallel connection conditions of synchronous generators?The fuel-cost curves for two generators are given as follows: C1(P1)=600+18P1+0.04(P1)2C2(P2)=700+20P2+0.03(P2)2 Assuming the system is lossless, calculate the optimal dispatch values of P1 and P2 for a total load of 1000 MW, the incremental operating cost, and the total operating cost.
- For Problem 3.18, the motor operates at full load, at 0.8 power factor leading, and at a terminal voltage of 10.45 kV. Determine (a) the voltage at bus 1, which is the generator bus, and (b) the generator and motor internal EMFs.Explain the concept of economic dispatch in power systems. How does it optimize the generation of power in a multi-generator system?Explain the concept of load transfer between the DC generators operating in parallel using load -voltage characteristics.
- 1- Static synchronous compensator (STATCOM) for powe factor improvement. 2- What is penalty factor? Derive the expression for the penalty factor in economic load dispatch.Discuss the double field revolving theory and discuss the equivalent circuit diagram of single phase induction motorA 100KVA, 6.6 kV 3 PHASE star connected cylindrical pole synchronous generator has 20-ohm as synchronous reactance and the armature resistance is negligible and the generator is working at the full load and unity power factor then find the value of the induced emf voltage(line to line).
- A 3 phase 4MVA, 12 kV star connected synchronous generator has Zs= 0.8+J30 ohm. Using circle diagram only, find: 1. The output power developed at unity power factor with excitation equal to 1.25 of rated voltage. 2. The load angle and power factor if the generator supplies (1500 KW) at rated voltage and excitation lequal to (1.2) of rated voltage. 3. Repeat part (2) when .armature resistance is neglected14. How does field distortion affect commutation ? ( DC GENERATOR QUESTION)a) 3-phase star-connected synchronous generator supplies a current of 10A having phase angle of 20° lagging 400V (phase voltage). Given the direct and quadrature axis reactances as 10ohms and 6.5ohms respectively and neglecting armature resistance, Find: 1. The load angle 2 The direct and quadrature components of armature currents 3. Voltage regulation