Question 3) A 200 km Three-Phase 50 Hz transposed transmission line is composed of one ACSR, 1,431,000 cmil, 47/7 Bobolink conductors as shown in Figure 3 (a).The Three-Phases have flat horizontal spacing of 11 meters as shown in the Figure. The conductors have a diameter of 3.625 cm and a GMR of 1.439 cm. The Line is going to be replaced with a three conductor bundle of ACSR, 477,000 cmil, 26/7 Hawk conductors. The conductors have a diameter of 2.1793 cm and a GMR of 0.8839 cm. The new line will have an increased horisontal phese spacing of 14 meters as it is going to be operated at higher Voltage rating. The new line is shown in Figure 3 (b). The spacing between the bundles in Figure 3 (b) is 45 cm. Determine, a) The inductance for each case and the percentage change in inductance b) The inductive reactance for each line and the percentage change. c) *Comment on your results. b 11 m 11 m Figure 3 (a) 14 m 14 m

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter5: Transmission Lines: Steady-state Operation
Section: Chapter Questions
Problem 5.12P
icon
Related questions
icon
Concept explainers
Question

please help me all option is step by step solve thank you

Question 3) A 200 km Three-Phase 50 Hz transposed transmission line is
composed of one ACSR, 1,431,000 cmil, 47/7 Bobolink conductors as shown in
Figure 3 (a).The Three-Phases have flat horizontal spacing of 11 meters as
shown in the Figure. The conductors have a diameter of 3.625 cm and a GMR
of 1.439 cm. The Line is going to be replaced with a three conductor bundle of
ACSR, 477,000 cmil, 26/7 Hawk conductors. The conductors have a diameter
of 2.1793 cm and a GMR of 0.8839 cm. The new line will have an increased
horisontal phese spacing of 14 meters as it is going to be operated at higher
Voltage rating. The new line is shown in Figure 3 (b). The spacing between the
bundles in Figure 3 (b) is 45 cm. Determine,
a) The inductance for each case and the percentage change in inductance
b) The inductive reactance for each line and the percentage change.
c) *Comment on your results.
b
11 m
11 m
Figure 3 (a)
a
14 m
14 m
Transcribed Image Text:Question 3) A 200 km Three-Phase 50 Hz transposed transmission line is composed of one ACSR, 1,431,000 cmil, 47/7 Bobolink conductors as shown in Figure 3 (a).The Three-Phases have flat horizontal spacing of 11 meters as shown in the Figure. The conductors have a diameter of 3.625 cm and a GMR of 1.439 cm. The Line is going to be replaced with a three conductor bundle of ACSR, 477,000 cmil, 26/7 Hawk conductors. The conductors have a diameter of 2.1793 cm and a GMR of 0.8839 cm. The new line will have an increased horisontal phese spacing of 14 meters as it is going to be operated at higher Voltage rating. The new line is shown in Figure 3 (b). The spacing between the bundles in Figure 3 (b) is 45 cm. Determine, a) The inductance for each case and the percentage change in inductance b) The inductive reactance for each line and the percentage change. c) *Comment on your results. b 11 m 11 m Figure 3 (a) a 14 m 14 m
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning