QUESTION 8 The counter program shown is designed to: L1 Inputs PB1 foto PBZ Ladder logic program PB1 C5:0/DN B3:0/0 CTU HEE OSA COUNT-UP COUNTER Counter Preset Accumulated PB2 B3:0/0 OSA C5:0/DN C5:1/DN 36 36 C5:1 32000 0 O count below the maximum count allowed per counter. O count beyond the maximum count allowed per counter. count up and count down. record the time of an event. CTU COUNT-UP COUNTER (cu Counter ON) Preset Accumulated |(cu) (ON) C5:0 32000 0 PL C5:0 (RES) C5:1 (RES Output PL L2

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question
Question 8
O only when the accumulated value exceeds 10.
O only when the accumulated value is zero.
O until the accumulated value equals the preset value.
O when the accumulated value equals the preset value.
QUESTION 8
The counter program shown is designed to:
L1
Inputs
36
PB1
PB2
Ladder logic program
PB1 C5:0/DN B3:0/0
CTU
HEE OSA COUNT-UP COUNTER
Counter
Preset
Accumulated
B3:0/0
OSA
C5:0/DN C5:1/DN
3636
PB2
36
O count below the maximum count allowed per counter.
O count beyond the maximum count allowed per counter.
O count up and count down.
O record the time of an event.
C5:1 (ON)
32000
0
C5.1
(RES)
CTU
COUNT-UP COUNTER (Cu)
Counter
(ON)
Preset
Accumulated
C5:0
32000
0
PL
C5:0
(RES)
C5:1
(RES)
QUESTION 9
The output Lot Full Light will be energized when the accumulated count is:
Output
PL-
L2
Transcribed Image Text:O only when the accumulated value exceeds 10. O only when the accumulated value is zero. O until the accumulated value equals the preset value. O when the accumulated value equals the preset value. QUESTION 8 The counter program shown is designed to: L1 Inputs 36 PB1 PB2 Ladder logic program PB1 C5:0/DN B3:0/0 CTU HEE OSA COUNT-UP COUNTER Counter Preset Accumulated B3:0/0 OSA C5:0/DN C5:1/DN 3636 PB2 36 O count below the maximum count allowed per counter. O count beyond the maximum count allowed per counter. O count up and count down. O record the time of an event. C5:1 (ON) 32000 0 C5.1 (RES) CTU COUNT-UP COUNTER (Cu) Counter (ON) Preset Accumulated C5:0 32000 0 PL C5:0 (RES) C5:1 (RES) QUESTION 9 The output Lot Full Light will be energized when the accumulated count is: Output PL- L2
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY