Retention times with a 1.10 m gas-liquid chromatographic column: air, 18.0 s; methyl acetate, 1.98 min.; methyl propionate, 2.24 min; methyl n-butyrate, 7.93 min.Base widths of the last three peaks: 0.19; 0.23 and 0.79 min, respectively. Calculate:a) the value of k for each compound,b) the alpha value for each pair of adjacent peaks,c) the theoretical number of plates and the plate height of each column;d) the resolution of every two adjacent compounds.

EBK A SMALL SCALE APPROACH TO ORGANIC L
4th Edition
ISBN:9781305446021
Author:Lampman
Publisher:Lampman
Chapter88: Column Chromatography
Section: Chapter Questions
Problem 4P
icon
Related questions
Question
100%

Retention times with a 1.10 m gas-liquid chromatographic column: air, 18.0 s; methyl acetate, 1.98 min.; methyl propionate, 2.24 min; methyl n-butyrate, 7.93 min.
Base widths of the last three peaks: 0.19; 0.23 and 0.79 min, respectively. Calculate:
a) the value of k for each compound,
b) the alpha value for each pair of adjacent peaks,
c) the theoretical number of plates and the plate height of each column;
d) the resolution of every two adjacent compounds.

AI-Generated Solution
AI-generated content may present inaccurate or offensive content that does not represent bartleby’s views.
steps

Unlock instant AI solutions

Tap the button
to generate a solution

Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning