Substances A and B have retention times of 16.40 and 17.63 minutes, in a 30.0 cm column. A species that is not retained passes through the column in 1.30 minutes. The peak widths (at the base) for A and B are 1.11 and 1.21 minutes.Calculate:a) Resolution of the columnb) Average number of plates in the column.c) Height of the plate.d) Time required to elute substance B in a column that gives a resolution value, Rs = of 1.5.

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter31: Introduction To Analytical Separations
Section: Chapter Questions
Problem 31.32QAP
icon
Related questions
Question

Substances A and B have retention times of 16.40 and 17.63 minutes, in a 30.0 cm column. A species that is not retained passes through the column in 1.30 minutes. The peak widths (at the base) for A and B are 1.11 and 1.21 minutes.
Calculate:
a) Resolution of the column
b) Average number of plates in the column.
c) Height of the plate.
d) Time required to elute substance B in a column that gives a resolution value, Rs = of 1.5.

AI-Generated Solution
AI-generated content may present inaccurate or offensive content that does not represent bartleby’s views.
steps

Unlock instant AI solutions

Tap the button
to generate a solution

Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage