this represents an OLTC system, taken from the matlab program, explain what the elements used are, and why

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.1P: Given the complex numbers A1=630 and A2=4+j5, (a) convert A1 to rectangular form: (b) convert A2 to...
icon
Related questions
Question
100%

this represents an OLTC system, taken from the matlab program, explain what the elements used are, and why it is used for the OLTC system.

 

 

a power_OLTCregtransformer - Simulink
SIMULATION
DEBUG
MODEUNG
FORMAT
APPS
BLOCK
O Open
Stop Time 120
G Save -
Normal
Signal
Table
Data
Log
Signals
Bird's-Eye
Scope
Add
Logic
Analyzer
New
Library
Browser
Step
Run
Step
Stop
A Print -
Viewer
Fast Restart
Back -
Forward
Inspector
FILE
LIBRARY
PREPARE
SIMULATE
REVIEW RESULTS
power_OLTCregtransformer
e a power OLTCregtransformer
Model 1: Detailed model
Таp1
V1_82
Vm (pu)
Таp
Тар1
A
(A
000
a
NVB
B-W-Wb
dB
bp
120 kV
1000 MVA
B1
B2
3 30-km feeders
Three-Phase OLTC
Regulating Transformer
Yg/Delta (D1)
47 MVA 120/25 kV
ABC
25 kV
36 MW
25 kV
15Mvar
10 Mvar
Model 2: Phasor model
Тар2
V1_84
Vm (pu)
Тар2
mi
<Tap>
Alle
al
B-W-W-b
1000 MVA
B3
B4
3 30-km feeders
Тар1
Tap1 Tap2
Yg/Delta (D1)
47 MVA 120/25 kV
Тар2
25 kV
36 MW
25 kV
15Mvar
VB1 B2 B4 (pu)
VB1 B2 84 (pu)
10 Mvar
PB1 B3 (MWn
PB1 B3 (MW)
о В1 в (Муar
QB1 B3 (MWn
Signal Processing
Scope
Phasor
60 Hz
Phasor Simulation of On Load Tap Changer (OLTC) Regulating Transformers
>>
Ready
121%
ode23tb
|國
Transcribed Image Text:a power_OLTCregtransformer - Simulink SIMULATION DEBUG MODEUNG FORMAT APPS BLOCK O Open Stop Time 120 G Save - Normal Signal Table Data Log Signals Bird's-Eye Scope Add Logic Analyzer New Library Browser Step Run Step Stop A Print - Viewer Fast Restart Back - Forward Inspector FILE LIBRARY PREPARE SIMULATE REVIEW RESULTS power_OLTCregtransformer e a power OLTCregtransformer Model 1: Detailed model Таp1 V1_82 Vm (pu) Таp Тар1 A (A 000 a NVB B-W-Wb dB bp 120 kV 1000 MVA B1 B2 3 30-km feeders Three-Phase OLTC Regulating Transformer Yg/Delta (D1) 47 MVA 120/25 kV ABC 25 kV 36 MW 25 kV 15Mvar 10 Mvar Model 2: Phasor model Тар2 V1_84 Vm (pu) Тар2 mi <Tap> Alle al B-W-W-b 1000 MVA B3 B4 3 30-km feeders Тар1 Tap1 Tap2 Yg/Delta (D1) 47 MVA 120/25 kV Тар2 25 kV 36 MW 25 kV 15Mvar VB1 B2 B4 (pu) VB1 B2 84 (pu) 10 Mvar PB1 B3 (MWn PB1 B3 (MW) о В1 в (Муar QB1 B3 (MWn Signal Processing Scope Phasor 60 Hz Phasor Simulation of On Load Tap Changer (OLTC) Regulating Transformers >> Ready 121% ode23tb |國
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Diode-Transistor Logic Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning