Water enters at 20 ℃ at a rate of 0.2 kg/s in a double-pipe parallel flow heat exchanger is to be heated to 70 ℃ by geothermal water that enters the heat exchanger at 155 ℃ at a rate of 0.3 kg/s. The overall heat transfer coefficient of the heat exchanger is 500 W/m2. ℃. The internal diameter of the tube is 1.2 cm. Determine the length of the heat exchanger. The specific heats of the water and geothermal water are given to be 4.18 and 4.31 kJ/kg.℃, respectively. Select one: a. 25.4 m b. 30.5 m c. 20.7 m d. 27.5 m

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.32P
icon
Related questions
Question
100%
Water enters at 20 ℃ at a rate of 0.2 kg/s in a double-pipe parallel flow heat exchanger is to be heated to 70 ℃ by geothermal water that enters the heat exchanger at 155 ℃ at a rate of 0.3 kg/s. The overall heat transfer coefficient of the heat exchanger is 500 W/m2. ℃. The internal diameter of the tube is 1.2 cm. Determine the length of the heat exchanger. The specific heats of the water and geothermal water are given to be 4.18 and 4.31 kJ/kg.℃, respectively. Select one: a. 25.4 m b. 30.5 m c. 20.7 m d. 27.5 m
Water enters at 20 °C at a rate of 0.2 kg/s
in a double-pipe parallel flow heat
exchanger is to be heated to 70 °C by
geothermal water that enters the heat
exchanger at 155 °C at a rate of 0.3 kg/s.
The overall heat transfer coefficient of
the heat exchanger is 500 W/m2. °C. The
internal diameter of the tube is 1.2 cm.
Determine the length of the heat
exchanger. The specific heats of the
water and geothermal water are given to
be 4.18 and 4.31 kJ/kg.°C, respectively.
Select one:
a. 25.4 m
b. 30.5 m
c. 20.7 m
d. 27.5 m
1:10 am
Transcribed Image Text:Water enters at 20 °C at a rate of 0.2 kg/s in a double-pipe parallel flow heat exchanger is to be heated to 70 °C by geothermal water that enters the heat exchanger at 155 °C at a rate of 0.3 kg/s. The overall heat transfer coefficient of the heat exchanger is 500 W/m2. °C. The internal diameter of the tube is 1.2 cm. Determine the length of the heat exchanger. The specific heats of the water and geothermal water are given to be 4.18 and 4.31 kJ/kg.°C, respectively. Select one: a. 25.4 m b. 30.5 m c. 20.7 m d. 27.5 m 1:10 am
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Heat Exchangers
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning