Water with a flow rate of 225 kg / h and a specific temperature of 4188 J / kgK is heated by a body-tube heat exchanger with cross flow from 35 K to 85 K. In the heat exchanger, 8 pipes with a diameter of 100 mm pass through the body 10 times. Oil with a flow rate of 225 kg / h, a temperature of 210 K and a specific temperature of 2095 J / kgK will be used as a hot fluid. If the total heat transfer coefficient is 555 W / m2K, what is the pipe length? Take the correction factor of 0.78
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
Water with a flow rate of 225 kg / h and a specific temperature of 4188 J / kgK is heated by a body-tube heat exchanger with cross flow from 35 K to 85 K. In the heat exchanger, 8 pipes with a diameter of 100 mm pass through the body 10 times. Oil with a flow rate of 225 kg / h, a temperature of 210 K and a specific temperature of 2095 J / kgK will be used as a hot fluid. If the total heat transfer coefficient is 555 W / m2K, what is the pipe length? Take the correction factor of 0.78
Step by step
Solved in 3 steps