Which of the following areas require a GFCI? Check all that apply. bathroom V kitchen finished basement wet bar
Q: here are 240 square meters of floor area in a house that contains an electric range rated as 12 kW…
A: total floor area =240 square meter electric range =12 kW electric dryer =5000 W
Q: Receptacles installed in bathrooms are required to be GFCI protected, either by installing GFCI…
A: it is necessary that Receptacles installed in bathrooms are required to be GFCI protected, either by…
Q: When applying the general provisions for receptacle spacing to the rooms of a dwelling unit, which…
A: Article NEC 210.52(A)(1) states that the receptacles shall be installed such that no point measured…
Q: all ____ receptacle outlets used in technical applications shall be gfci protacted .
A:
Q: You are asked to replace an ungrounded receptacle (two wire) and there is not a source of ground…
A: The NEC Per sec.210-7(d)(3) allows the following installations while replacing the 2-wire…
Q: 20
A:
Q: A string of Suspension Insulators consists of 6 units. If the Voltage across the string is 34 KV and…
A: Given in the question: Voltage across the string = 34KV Voltage across the unit nearest to the line…
Q: When an individual branch circuit supplies a counter-mounted cooking unit, what Code reference tells…
A: Branch circuits for household cooking appliances are permitted to be inaccordance with Table 220.55.…
Q: You have determined that a 4700-ohm, 1⁄2-watt resistor on an electronic cir- cuit board is…
A: Given: A 4700-ohm, 1⁄2-watt resistor on an electronic circuit board is defective. Assuming room…
Q: Draw the class diagram for the following scenario. ' A Customer is having a bank account, that…
A: It is given that: A customer is having a bank account which can be savings account or current…
Q: Where Type MI cable terminates, a seal shall be provided immediately after stripping to prevent the…
A: MI cable is an assembly of conductors insulated with a highly compressed refractory mineral…
Q: The interior of a raceway installed on the outside of a building exposed to the weather O (Dry) O…
A: permitted, installing cables of entirely nonmetallic sheaths into the top of a surface-mounted…
Q: What is the maximum number of 15 ampere lighting circuits required if the dwelling has an occupied…
A: Refer the table 220.12 from the NEC, the minimum load requirements for the dwelling load unit is,
Q: A cooktop exhaust fan may be wired as a load on the GFCI protected small-appliance kitchen counter…
A: A statement is given in the question. We need to choose the correct option.
Q: 11. True or False: The ratio for a straight ladder is 1’ to 4’ (1:4) 12. What does GFCI stand for?…
A: 11- It is true that the ratio for a straight ladder is 1’ to 4’. This will cause the ladder to…
Q: 4.a. The ___ calculated load is rarely placed on an electrical system. A. optional B. standard C.…
A: An electrical load is a part of a circuit or an electrical component that uses electricity.…
Q: f a grounding means does not exist in outlet, nongrounding-type receptacle can be replaced with GFCI…
A: As per NEC 2017, when the grounding conductor does not exist in the receptacle enclosure there is…
Q: 17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: Draw the wiring diagram for controlling a florescent lamp from three location and Ai conditioner…
A: The wiring diagram for controlling a fluorescent lamp from three location:
Q: Identification All answers must be in accordance to NEC of the Philippines 1. What is the minimum…
A: Since you have posted a question with multiple sub-parts, we will solve the first three sub-parts…
Q: 1. What circuits supply the garage? 2. What are the circuit ratings? 3. How many GFCI-protected…
A: 1. The circuit B14 originates at panel B (15 Amp circuit) supplies the garage. The branch circuit is…
Q: here are 240 square meters of floor area in a house that contains an electric range rated as 12 kW…
A: It is given that: Total floor area=240 m2Electric range=12 KW=12000 WElectric dryer rating=5000 W
Q: If a grounded surface metal box makes direct contact with the mounting strap for a switch or…
A: Given that metal box makes direct contact with the mounting strap for a switch or receptacle and…
Q: 20- The protection element used in the method based on the current flowing from this weak point to…
A: Arc Extinguishing Coil: In a circuit breaker, the current carrying contacts when moved apart create…
Q: Suggest the suitable sub-station , when the atmosphere is polluted. O a. Pole Mounted sub-station O…
A: Correct option is indoor sub-station indoor substation are usually used where the surrounding…
Q: where must gfci receptacles be installed in residential garages
A: The GFCI stands for Ground Fault Circuit Interrupter. The GFCI receptacle is used to protect the…
Q: You are asked to replace an ungrounded receptacle (two wire) and there is not a source of ground…
A: The NEC Per sec.210-7(d)(3) allows the following installations while replacing the 2-wire…
Q: Discuss what is meant by zones of protection
A:
Q: Explain how to wire residential panels, lighting, receptacles, GFCI circuit breakers, and 240 Vac…
A: Electrical wiring is done in residential buildings to provide power for lights, fans, pumps, and…
Q: Q.7: Air-condition system being in every organization. How the Maintenance of Air Conditioning…
A: Here we discuss about maintenance procedure of AC systems in offices & the preventive measures…
Q: 24. What value is to be considered for a "don't care condition"?
A: The correct option along with the explanation is provided in the following section.
Q: when a freezer is plugged into a receptacle. be sure that the receptacle is pretcected by a gfc
A:
Q: Describe a situation where a GFCI would not trip and you could become injured.
A: The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker that may cut off…
Q: National Electrical Code's
A:
Q: 11. Calculate Earthing Resistance of Earthing strip/wire of 36 mm Diameter, 262 meter long buried at…
A: Given Diameter of the wire w=36 mm=3.6 cm Length of the conductor L=262 m=26200 cm Depth of the…
Q: If you stuck a paperclip in each of the two slots of a GFI-protected outlet, then grabbed one…
A: The GFI-protected outlet measures the small change in the current in the circuit and then breaks the…
Q: 1. The only exception to the need for all information technology equipment to be satisfactorily…
A: Note: We are authorized to answer the first question since the exact one wasn’t specified. Please…
Q: INFE242 ELECTRONICS PLEASE MAKE SURE THE ANSWER IS CORRECT i put this course 3 times and all the…
A: Vs = Vi Vd > 0 diode will turn on Vd <0 diode wheel turn off . Here we have two diodes…
Q: When compliance. you are required to complete an assessment of safety and environmenta Hiring…
A: Safety: The condition of being protected from unfamiliar and unlikely danger, risk and injury.…
Q: All of the following can provide GFCI protection for kitchen countertop convenience receptacles…
A: The National Electrical Code has provided the rules to use the ground-fault circuit interrupters…
Q: Explain each option & Choose the correct option. 4) The _ calculated load is rarely placed on an…
A: Aim To solve the three mcqs along with the necessary reason::
Q: Q3. A manufacturing plant producing pressurised oxygen canisters uses 3 ultrasonic detectors to…
A:
Q: A sound level meter is placed in front of a loudspeaker of a 60W audio system reads 70dB. All else…
A: Energy travels from one point to other in the form of vibrations. Sound wave is one such form of the…
Q: If a grounding means does not exist in an electrical outlet, a nongrounding-type receptacle can be…
A:
GFCI stands for Ground Fault Circuit Interrupter.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- All of the following can provide GFCI protection for kitchen countertop convenience receptacles EXCEPT:__________. Select one: a. AFCI/GFCI circuit-breakers b. by installing a single feed-through type GFCI receptacle to protect downstream receptacles c. AFCI circuit-breakers d. GFCI circuit-breakersReceptacles installed in bathrooms are required to be GFCI protected, either by installing GFCI receptacles or GFCI circuit breakers in the panelboard per... A. NEC 205.3 B. NEC 208.3 C. NEC 212.14 D. NEC 210.11(C) (3)11. True or False: The ratio for a straight ladder is 1’ to 4’ (1:4) 12. What does GFCI stand for? 13. At what amperage differences will a GFCI trip?
- all ____ receptacle outlets used in technical applications shall be gfci protacted .f a grounding means does not exist in outlet, nongrounding-type receptacle can be replaced with GFCI device, but it must be marked " ." A.Nongrounding GFCI B. Externally Grounded C. No Grounding Protection D. GFCI ProtectedA homeowner calls in an electrical contractor to install a separate circuit in the basement (unfinished) for a freezer. Is GFCI protection of the receptacle required? __________________________________________________________________________
- when calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load used for floor lamps, table lamps, and so fourthhere are 240 square meters of floor area in a house that contains an electric range rated as 12 kW and an electric dryer rated at 5000 watts. Calculate (a) the minimum size of feeders (service conductors) required.You have determined that a 4700-ohm, 1⁄2-watt resistor on an electronic cir- cuit board is defective. Assuming room permits, can the resistor be replaced with a 4700-ohm, 1-watt resistor without damage to the rest of the board, or will the higher wattage resistor generate excessive heat that could damage other components?
- Please answer in typing format please ASAP for the like please clear the solution Thanks in advance for your positive response from my sideWhat demand factor may be applied when four or more fixed appliances are connected to a service, in addition to an electric range, air conditioner, clothes dryer, or space-heating equipment? (220.53) ____You have determined that a 4700-ohm, 1/2-watt resistor on an electronic circuit board is defective. Assuming room permits, can the resistor be replaced with a 4700-ohm, 1-watt resistor without damage to the rest of the board, or will the higher wattage resistor generate excessive heat that could damage other components?