Which statement below is not true for a liquid-membrane based ion-selective electrode? ● A. Two reference electrodes measure the voltage difference across the ion-selective electrode organic polymer membrane. B. The organic polymer membrane separates the inner solution from the outer analyte solution. C. The organic polymer membrane is hydrophobic and is impregnated with a viscous organic solution containing an ion exchanger and sometimes a ligand specific for the analyte ion. O D. The potential difference across the organic polymer membrane occurs when the analyte ions embedded in the membrane diffuse into the inner aqueous solution creating a junction potential. O E. The potential difference is dependent only on the activity of anallyte ion in the outer solution.

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter23: Potentiometry
Section: Chapter Questions
Problem 23.14QAP
icon
Related questions
Question
Which statement below is not true for a liquid-membrane based ion-selective electrode?
●
●
A. Two reference electrodes measure the voltage difference across the ion-selective electrode organic polymer membrane.
B. The organic polymer membrane separates the inner solution from the outer analyte solution.
C. The organic polymer membrane is hydrophobic and is impregnated with a viscous organic solution containing an ion exchanger
and sometimes a ligand specific for the analyte ion.
D. The potential difference across the organic polymer membrane occurs when the analyte ions embedded in the membrane diffuse
into the inner aqueous solution creating a junction potential.
E. The potential difference is dependent only on the activity of anallyte ion in the outer solution.
Transcribed Image Text:Which statement below is not true for a liquid-membrane based ion-selective electrode? ● ● A. Two reference electrodes measure the voltage difference across the ion-selective electrode organic polymer membrane. B. The organic polymer membrane separates the inner solution from the outer analyte solution. C. The organic polymer membrane is hydrophobic and is impregnated with a viscous organic solution containing an ion exchanger and sometimes a ligand specific for the analyte ion. D. The potential difference across the organic polymer membrane occurs when the analyte ions embedded in the membrane diffuse into the inner aqueous solution creating a junction potential. E. The potential difference is dependent only on the activity of anallyte ion in the outer solution.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Potentiometric Titrations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Chemistry: The Molecular Science
Chemistry: The Molecular Science
Chemistry
ISBN:
9781285199047
Author:
John W. Moore, Conrad L. Stanitski
Publisher:
Cengage Learning
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage