-12 Evaluate the value of the twiddle factor W 32
Q: Power factor is 0.707 when three-phase inductive 250 kW power is drawn from 440 V transmission line.…
A: According to the question we have to find the current and power factor drawn from the line.
Q: U1 U1 (A1) U2 3-Phase Load U2 Variable (A2 3-Phase U3 U3 Supply (АЗ) N An Fig.1.
A:
Q: Which one of the following elements in a power system can generate VARS ? OA.LV transmission lines…
A: In this question we will write which elements generate VARs...
Q: Distribution Systems rses / Electrical Engineering / Power Distribution Systems / General / M…
A: In a power system, there are two systems called single phase system and three phase system. In three…
Q: 18V lav d 24V
A:
Q: ww v, 202 152 ww 302 50 mH
A:
Q: Predict the wattmeter readings for the circuit in Fig. z 208/0° V W2 208/-60° V Z = 60 – j30 2 ll…
A: Dear student as per our guidelines we are supposed to solve only one question.kindly repost other…
Q: A load consists of R=78 Q, XL=71 Q and Xc=47 Q. All the elements are connected in parallel across…
A:
Q: 32 42 TGV 12V
A:
Q: 452 2. 34j2 Zea Find the equivalent impedance
A:
Q: Use wye-delta/delta-wye transformation to determine the value of current i and equivalent resistance…
A: In this question , we will find equivalent resistance and current i .....
Q: A balanced 3-phase load of 30 MW is supplied at 132.1 kV and 0.85 pf lagging by means of…
A: From the General expression of Percentage voltage Regulation
Q: The example of a nearly equivalent uniformly distributed load on feeder is domestic load on a 3-…
A: uniformly distributed loads mean a large number of loads of the same wattage connected to the…
Q: Four industrial centers are located at the corners of a square of 26 km side. The loads are 4000 kW,…
A: The industrial centers are located at the corners of the given square. The best location of the…
Q: R1 R2 Vx 100/0 v 0,8Vx +1
A: Given
Q: A balanced star-connected load of (8 + j6) N per phase is connected to a balanced 3-phase 400-V…
A:
Q: The unbalanced Y-load of Fig. 12.23 has balanced voltages of 100 V and the acb sequence. (a) Predict…
A: A circuit diagram of a Y-connected unbalanced load with balanced voltages is given in the question.…
Q: a. Find the total number of watts, volt-amperes reactive, and volt-amperes, and the power factor F.…
A:
Q: In the circuit shown, convert to current-source conductive circuit and using node analysis determine…
A:
Q: Q -4 Balanced load fed by three phase system (Vab = 230 V) with abc sequence, the load (4+J15),…
A:
Q: 3)The two-wattmeter method gives Pi=1200 W and P2=400 W for a three-phase motor running on a 240-V…
A:
Q: 1. With neat diagram, discuss the 3-phase power measurement using three wattmeter method and write…
A:
Q: A balanced Y-connected load having an impedance of 72+j21 Ω/ ϕ is connected in parallel with a…
A: Given on delta connected load side per phase impedance (Z∆)=150∠0° Ω on star connected load side per…
Q: Which of the following mathematically represents the relationship between the phase and line…
A:
Q: 4. For the Figure shown below, determine nodal voltages using Nodal Analysis. 40 SA 120 4A ww ww ww
A: In the given circuit there are 3 nodes exists. Out of which one node is taken as reference in nodal…
Q: An overhead 3-phase transmission line delivers 5000 kW when a current of 150 A is flowing through…
A: The solution is as follows.
Q: Which of the following mathematically represents the relationship between the phase and line…
A: Correct option is C As the 3 phase motor connected in WYE configuration, we know that the phase and…
Q: A balanced, 3-phase, star connected load of 150 kW takes a leading current of 100 A, with a line…
A: For star-connected load Phase voltage=Line voltage3Phase current=Line currentImpedance…
Q: A balanced Y-connected load absorbs in total 3 kw at a power factor of 0.6 lagging. If the line…
A: Given: A balanced star connected load Total power absorbed, P=3 kW Power factor, cosϕ=0.6 lag Line…
Q: The load to the three phase supply comprises three similar coils connected in Star. The line current…
A: From given kva and kw calculate phase and line voltage and KVAR. Power factor =active power/apparent…
Q: 12 22 Ω 90 2 50 V 42 ww ww
A: a) The equivalent resistance seen by the source can be calculated as: First,solve the parallel of…
Q: Use wye-delta/delta-wye transformation to determine the value of current i and equivalent resistance…
A: In this question, We need to determine the current i and equivalent resistance? We are solving…
Q: By Nodal Analysis, determine the voltage V₂ of the circuit V, 252 jsr V₂ 8410A 52² 3452 1 jior 20r…
A: The solution is given below
Q: A balanced Y-connected load absorbs in total 3 kW at a power factor of 0.6 lagging. If the line…
A: Given: A balance Y-connected load has PL=3 kWcosθ=0.6VL=500 V
Q: 12.39 Find the real power absorbed by the load in Fig. 12.58. A ps ww -j6 Q 100/120° V 100/0° V j3Q…
A:
Q: Predict the wattmeter readings for the circuit in Fig. 208/0° V W2 208/-60° V Z = 60 - j30 2 all N
A: Applying mesh analysis in loop 1, 208∠0°=2ZI1-ZI2......1 Applying mesh analysis in loop 2,…
Q: Detesmine the system functions of the two networks in figuse and show that they Same poles. have the…
A: 1) Network 1 we will calculate the transfer function as we can see in fig. 4(a)
Q: i. Obtain the parameters of the equivalent circuit, Find the full-load copper and iron losses. ii.…
A: The transformer is astatic device, which transfers the electric energy from one circuit to another…
Q: What is the phase sequence of a three-phase alternator connected in Y for which e,. moreover find…
A: Given, VAN=7200∠-130 VVBN=7200∠110 V
Q: An overhead 3-phase transmission line delivers 6000 kW when a current of 180 A is flowing through…
A: The solution can be achieved as follows.
Q: Example 9.6 For the power system below, draw the zero sequence networks. Q W △ Y글 Y M P R S △ Y글
A: The solution is given below
Q: Three identical loads having an impedance of (8.66 + j5) are connected in wye across a balanced…
A: Given: Impedance, Z=(8.66 + j5)Ω Line voltage, VL=330V
Q: 30. Which are used for power factor correction in industrial applications? a. farads b. capacitors…
A:
Q: USE NODE VOLTAGE METHOD CNODAL ANALYgis) 124
A:
Q: A balanced delta connected load, consisting of there coils, draws 10-√3 A at 0.5 power factor from…
A:
Q: In polyphase generation of power simultaneous multiple voltages are generated with a phase angle of…
A: In polyphase generation of power, simultaneous multiple voltages are generated with the phase angle…
Q: (wt + 68") amp respectively, BAC circuit. What is the impedance of a balanced wye connected load and…
A: The solution is given below
Q: B - A balanced star - connected load of (4 + j3) N( ohm ) per phase is connected to a balanced…
A: In a three phase system there are two ways to connect a three phase load. Star/Wye Connection Delta…
Step by step
Solved in 3 steps with 3 images
- Evaluate the following twiddle factor: W48Topic: Maximum Power Transfer Theorem for an AC Circuit A. Measure the current through and voltage across the loadon PR1. Calculate also the complex power at the load which is comprised of thereal power PL and reactive power QL.What should ZL be for the maximum power transfer in the circuit given below and calculate the maximum power
- Write the system of equations for the network using nodal analysis. Calculate the nodal voltages Find Ir1,Ir2, and p12AC bridge Find the Z4 with if , Z1 (Rx=3 ohm Cx= 0.00562 farad) , Z2 (Rs= 2 ohm Cs=0.00432 farad ) , Z3( R3= 5 ohm) , F= 1000 Hz. *Use source transformation to determine Vo as a result of the independent contribution from the voltage source Vs=18<90°. Give the answer in rectangular form
- Find ZL for maximum ave. power transfer (ac) and get the max ave power supplied....Show that the following property of the twiddle factor is valid: WNk+N=WNkDetermine the output impedance (Zo) for the given network with the following conditions: gfs = 3000uS and gos = 50uS. a. 10M-ohms b. 20K-ohms d. 3.33k-ohms d. 2.83k-ohms