2-6. A 1000-VA, 230/115-V transformer has been tested to determine its equivalent cir- cuit. The results of the tests are shown below. Open-circuit test (on secondary side) Voc 115 V loc = 0.11 A Poc = = 3.9 W Short-circuit test (on primary side) Vsc = 17.1 V 1sc = 8.7 A Psc = 38.1 W (a) Find the equivalent circuit of this transformer referred to the low-voltage side of the transformer. (b) Find the transformer's voltage regulation at rated conditions and (1) 0.8 PF lag- ging, (2) 1.0 PF, (3) 0.8 PF leading. (c) Determine the transformer's efficiency at rated conditions and 0 8 PF lagging

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.63P: A 23/230-kV step-up transformer feeds a three-phase transmission line, which in turn supplies a...
icon
Related questions
Question
current? Why?
2-6. A 1000-VA, 230/115-V transformer has been tested to determine its equivalent cir-
cuit. The results of the tests are shown below.
Open-circuit test
(on secondary side)
Voc = 115 V
loc = 0.11 A
Poc = 3.9 W
Short-circuit test
(on primary side)
Vsc = 17.1 V
1sc = 8.7 A
Psc = 38.1 W
(a) Find the equivalent circuit of this transformer referred to the low-voltage side of
the transformer.
(b) Find the transformer's voltage regulation at rated conditions and (1) 0.8 PF lag-
ging, (2) 1.0 PF, (3) 0.8 PF leading.
(c) Determine the transformer's efficiency at rated conditions and 0.8 PF lagging.
Transcribed Image Text:current? Why? 2-6. A 1000-VA, 230/115-V transformer has been tested to determine its equivalent cir- cuit. The results of the tests are shown below. Open-circuit test (on secondary side) Voc = 115 V loc = 0.11 A Poc = 3.9 W Short-circuit test (on primary side) Vsc = 17.1 V 1sc = 8.7 A Psc = 38.1 W (a) Find the equivalent circuit of this transformer referred to the low-voltage side of the transformer. (b) Find the transformer's voltage regulation at rated conditions and (1) 0.8 PF lag- ging, (2) 1.0 PF, (3) 0.8 PF leading. (c) Determine the transformer's efficiency at rated conditions and 0.8 PF lagging.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 9 steps with 9 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning